Télécharger Imprimer la page

MSW Motor Technics MSW-FI-7500 Manuel D'utilisation page 248

Publicité

Specification of high-performance vector convertor
P6-15
Only the built-in braking unit is valid.
Duty cycle, brake usage rate is used to adjust the movable unit, the high duty cycle operation of the braking unit, the braking
effect is strong, but the inverter braking bus voltage fluctuations.
P7 Group--Keyboard and Display
JOG key function selection
P7-01
Setting range
JOG key for the multi-function keys, you can set the JOG key functions via the function code. In the shutdown and can be
run through the key switch.
0: This key has no function.
1: Keyboard commands and remote operation switch. Means an order to switch the source, namely the current command
source and keyboard control (local operation) switch. If the current command source is keypad control, this key function is
disabled.
2: Reversible switching direction switching by frequency command JOG key. This feature is only command source
operation panel command channel is active.
3: Forward jog forward rotation Jog (FJOG) JOG key keyboard.
4: Reverse jog achieve reverse jog (RJOG) JOG key keyboard.
STOP / RESET key function
P7-02
Setting range
Brake usage
Setting range
Factory default
0
Operation panel command channel and remote command
1
channel (terminal command channel or command channel)
2
3
4
Factory default
Only in keyboard mode, STOP / RES key stop function effectively
0
1
In any operating mode, STOP / RES key stop function is valid
- 103 -
Factory default
0%~100%
JOG key is invalid
Reversing switch
Forward jog
Reverse jog
1
Parameter description
100%
0

Publicité

loading