Specification of high-performance vector convertor
P5-06
FMP output function selection (pulse output terminals)
P5-07
AO1 output function selection
P5-08
AO2 output function selection
FMP terminal pulse frequency output range is 0.01kHz ~ P5-09 (FMP maximum output frequency), P5-09 can be set
between 0.01kHz ~ 100.00kHz.
Analog outputs AO1 and AO2 output range is 0V ~ 10V, or 0mA ~ 20mA. Pulse output or analog output range, with the
corresponding scaling function relationship in the following table:
Set point
Operating frequency
0
Set frequency
1
Output current
2
Output torque
3
Output Power
4
Output voltage
5
6
7
8
9
10
The count value
11
Communication Preferences
12
Motor speed
13
Output current
14
Output voltage
15
FMP maximum output frequency
P5-09
When FM is selected as a pulse output terminal, the function code is used to select the maximum output pulse frequency
value.
P5-10
P5-11
P5-12
P5-13
Function
Pulse or analog output corresponding to 0.0% to 100.0% of the function
Pulse input
AI1
AI2
AI3
Length
Setting range
AO1 zero offset coefficient
Setting range
AO1 gain
Setting range
Expansion card AO2 zero offset coefficient
Setting range
Expansion card AO2 gain
Setting range
0 ~ maximum output frequency
0 ~ maximum output frequency
0~2 times Motor rated current
0 to 2 times rated motor torque
0-2 times of rated power
0 to 1.2 times the rated voltage of the inverter
0.01kHz~100.00kHz
0V~10V (or 0 ~ 20mA)
0 to the maximum set length
0 to the maximum count
0 ~ maximum output frequency corresponding to the rotational speed
Factory default
0.01kHz~100.00kHz
Factory default
-100.0%~+100.0%
Factory default
-10.00~+10.00
Factory default
-100.0%~+100.0%
Factory default
-10.00~+10.00
- 97 -
Parameter description
Factory default
Factory default
Factory default
0V~10V
0V~10V
0.0%~100.0%
0.0A~1000.0A
0.0V~1000.0V
50.00kHz
0.00%
0
0
1
0.0%
1.00
1.00