Télécharger Imprimer la page

MSW Motor Technics MSW-FI-7500 Manuel D'utilisation page 222

Publicité

Specification of high-performance vector convertor
P1 group: Parameters of 1
Type selection of motor
P1-00
Setting
range
Rated power
P1-01
Setting range
Rated voltage
P1-02
Setting range
Rated current
P1-03
Setting range
Rated frequency
P1-04
Setting range
Rated speed
P1-05
Setting range
The code for the motor nameplate parameters, both by VF control and vector control, are needed
to accurately set the relevant parameters according to the motor nameplate.
In order to obtain better VF or vector control performance, the need for parameter tuning, and
the accuracy of adjustment results, and properly set motor nameplate parameters closely.
Stator resistance of asynchronous motor
P1-
Setting range
Rotor resistance of asynchronous motor
P1-
Setting range
07
Leakage inductive reactance of
asynchronous motor
P1-
08
Setting range
Mutual inductive reactance of
asynchronous motor
P1-
09
Setting range
No-load current of asynchronous motor
P1-
Setting range
10
P1-06 ~ P1-10 is asynchronous motor parameters, these parameters generally do not have the motor
nameplate, auto-tuning to get through the drive. Among them, "Induction Motor static tuning" can only
get three parameters P1-06 ~ P1-08. But the "asynchronous motors complete tuning" can be obtained here
except all five parameters, you can also get the encoder phase sequence, current loop PI parameters and
others.
motor
st
Factory default
Common asynchronous motor
0
Variable frequency asynchronous motor
1
Factory default
0.1kW~1000.0kW
Factory default
1V~400V
Factory default
0.01A~655.35A (convertor power <=55kW)
0.1A~6553.5A (convertor power >55kW)
Factory default
0.01Hz~ max. frequency
Factory default
1rpm~65535rpm
Factory default
0.001Ω~30.000Ω
Factory default
0.001Ω~65.535Ω (convertor power <=55kW)
0.0001Ω~6.5535Ω (convertor power >55kW)
Factory default
0.01mH~655.35mH (convertor power <=55kW)
0.001mH~65.535mH (convertor power >55kW)
Factory default
0.1mH~6553.5mH (convertor power <=55kW)
0.01mH~655.35mH (convertor power >55kW))
Factory default
0.01A~ P 1-03 (convertor power <=55kW)
0.1A~P1-03 (convertor power >55kW)
Depend on machine type
Depend on machine type
Depend on machine type
Depend on machine type
Depend on machine type
Depend on machine type
Depend on machine type
Depend on machine type
Depend on machine type
Depend on machine type
- 77 -
Parameter description
0

Publicité

loading