Specification of high-performance vector convertor
2.6 Optional accessories
Name
External brake unit
Multifunction expansion
card
I/O expansion card
MODBUS communication
card
CANlink communication
expansion card
Interface card of
differencial encoder
Interface card of rotary
transformer
Interface card of open
collector encoder
Introduced LED operating
panel
Extension cable
2.7 Routine maintenance of frequency convertor
2.7.1 Routine maintenance
The influence of environment temperature, humidity, dust and vibration will lead to aging of internal
components and potential fault, or reduce lifespan of frequency convertor, so it's necessary to conduct routine
and regular maintenance.
Routine inspection items:
1) If any abnormal change of sound during motor operation
2) If any vibration during motor operation
3) If any change of installing environment for frequency convertor
4) If normal work of cooling fan for frequency convertor
5) If overheating of frequency convertor
2.7.2 Regular inspection
Regular inspection items:
1) Inspect air channel and clean regularly
2) Inspect if any loosening of screw
3) Inspect if any arc trace of wiring terminal
Table 2-6 Accessories of frequency convertor
Model
18.5kW and above external brake unit
SNBU
It can add five figures input and one
analog voltage input. AI3 is isolate
analog quantity that can connects with
IO-MINI-V03
PT100 and PT1000; one relay output,
one figure output and one analog
voltage output with RS485 / CAN
It can add three figures input
IO1
With isolating RS-485 communication
RS485
card
CANlink communication adapter card Suitable for whole series
CANLINK-
V03
Interface card of differencial rotary
PG1
encoder, adaptive for 5V power source
Suitable for rotating encoder, driving
PG2
frequency 10kHz, DB9 interface
Interface card of open collector
PG3
encoder, with 1: 1 frequency dividing
output, adaptive for 15V power source
Introduced LED display and operating
SNKE
keyboard
SNCAB
Introduced extension cable
Function
- 20 -
Product information
Remark
75kW and above
adopts multi-parallel
connection
Suitable for models of
3.7KW and above
Suitable for whole series
Suitable for whole series
Suitable for whole series
Suitable for whole series
Suitable for whole series
Suitable for SN series
Standard configuration 3
meter