Télécharger Imprimer la page

MSW Motor Technics MSW-FI-7500 Manuel D'utilisation page 207

Publicité

Specification of high-performance vector convertor
Code
Stator resistance of asynchronous
A2-06
motor
Rotor resistance of asynchronous
A2-07
motor
Leakage inductive reactance of
A2-08
asynchronous motor
Mutual inductive reactance of
A2-09
asynchronous motor
No-load current of asynchronous
A2-10
motor
Encoder line number
A2-27
A2-28
Encoder type
Speed feedback PG selection
A2-29
ABZ incremental encoder AB
A2-30
phase sequence
Pole-pairs number of rotary
A2-34
transformer
Speed feedback PG
A2-36
disconnection detection time
A2-37
Tuning selection
Speed loop proportional gain 1
A2-38
Speed loop integral time 1
A2-39
Switching frequency 1
A2-40
Speed loop proportional gain 2
A2-41
Speed loop integral time 2
A2-42
Switching frequency 2
A2-43
Vector control slip gain
A2-44
Speed loop filter time constant
A2-45
Vector control over excitation
A2-46
gain
Name
0.001 Ω ~65.535 Ω
(convertor power <=55kW)
0.0001Ω~6.5535Ω
(convertor power >55kW)
0.001 Ω ~65.535 Ω
(convertor power <=55kW)
0.0001Ω~6.5535Ω
(convertor power >55kW)
0.01mH~655.35mH
(convertor power <=55kW)
0.001mH~65.535mH
(convertor power >55kW)
0.1mH~6553.5mH
(convertor power <=55kW)
0.01mH~655.35mH
(convertor power >55kW)
0.01A~A2-03 (convertor power <=55kW)
0.1A~A2-03 (convertor power >55kW)
1~65535
0: ABZ incremental encoder
1: Reserved
2: Resolver
0: Local PG
1: Local PG
2: Pulse input (DI5)
0: Forward
1: Reverse
1~65535
0.0: no action
0.1s~10.0s
0: No operation
1: asynchronous machine static tuning
2: asynchronous machine complete tuning
1~100
0.01s~10.00s
0.00~A2-43
1~100
0.01s~10.00s
A2-40~ max. frequency
50%~200%
0.000s~0.100s
0~200
Setting range
- 62 -
Functional parameter table
Default
Change
machine type
machine type
machine type
machine type
machine type
1024
0
0
0
1
0.0
0
30
0.50s
5.00Hz
20
1.00s
10.00Hz
100%
0.000s
64