Télécharger Imprimer la page

MSW Motor Technics MSW-FI-7500 Manuel D'utilisation page 236

Publicité

Specification of high-performance vector convertor
Among them: SB1: stop button SB2: run the button
Terminal UP / DOWN rate of
P4-12
Setting
When setting terminal UP / DOWN adjust set frequency, the frequency rate of change, that is, the amount of change in
frequency per second.
When P0-22 (frequency decimal point) is 2, the value is in the range of 0.001Hz / s ~ 65.535Hz / s.
When P0-22 (frequency decimal point) is 1, the value is in the range of 0.01Hz / s ~ 655.35Hz / s.
AI curve 1 Minimum Input
P4-13
Setting
AI curve 1 minimum input corresponding
P4-14
settings
Setting
AI curve 1 maximum input
P4-15
Setting
AI curve 1 maximum input corresponding
P4-16
to set
Setting
AI1 filtering time
P4-17
Setting
The above function codes are used to set the analog input voltage setpoint relationship between its representatives.
When the analog input voltage is greater than the set "maximum input" (P4-15), the analog voltage in accordance with the
"maximum input" computing; similarly, when the analog input voltage is less than the set "minimum input" (P4-13),
according to "AI is below the minimum input setting Select" (P4-34) is set to the minimum input or 0.0% calculated.
When the analog input is current input, 1mA current corresponds to 0.5V.
AI1 input filtering time for setting AI1 software filtering time when the analog easily disturbed site, please increase the filter
time so that the analog detection stabilized, but the greater the filtering time of the analog detection slow response times, how
to set up a trade-off depending on the application.
In different applications, analog setting 100.0% of the nominal value of the corresponding meanings vary, please refer to the
description of each part of the application.
The following illustrates a case where two typical settings:
0.01Hz/s~65.535Hz/s
0.00V~P4-15
-100.00%~100.0%
P4-13~10.00V
-100.00%~100.0%
0.00s~10.00s
Factory default
Factory default
Factory default
Factory default
Factory default
Factory default
- 91 -
Parameter description
1.00Hz/s
0.00V
0.0%
10.00V
100.0%
0.10s