General data
Dimensions
Weight
Operating temperature range
Storage temperature range
Protection to EN 60529/IEC529
Compressed air quality
Working pressure
Nominal flow
Mounting orientation
Electrical data
Operating voltage
Electronics U
L
I
L
Load U
, U
Q1
Q2
Fuse protection for valve power supply
Fuse protection for electronics supply
Line length for power supply
Current in 0 V line
Internal voltage drop
Output current per valve output
No. of outputs
No. of output bytes
Start-up time
AVENTICS | CANopen | R402003660–BAL–001–AE
11 Technical data
Depend on configuration; see online catalogue.
Depend on configuration; see online catalogue.
0 °C to +50 °C, without condensation
–20 °C to +70 °C
When assembled: IP 69K
To DIN ISO 8573-1, class 6, 4, 3 or lower
solid pollutants: ≤ 5 μm
dew point: ≤ 3 °C
oil content: ≤ 1 mg/m
2.5 - 10 bar
950 - 1100 std. l/min, depending on valve type and subbase
at 6 bar pilot pressure, Δ = 1 bar
Any
24 V DC (+20%/-15%)
50 mA
24 V DC (±10%/±15%)
2 x 3.0 A (F)
500 mA (F)
Max. 20 m
Max. 4 A
0.6 V
Max. 100 mA
Max. 32
Fixed, output 4 bytes and input 0 bytes
Approx. 1 s
The corresponding declaration of conformity is included on CD
R412023902.
Technical data
3
95