Technical Data - Aventics SV01 Série Notice D'instruction

Distributeur de sécurité
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
AVENTICS | SV01/SV03/SV05 | R412027221-BAL-001-AA | English

12 Technical Data

General data
Dimensions (length x width x height)
Max. Weight
Design
Actuation
Flow Media
Operating Pressure Range
Ambient/Media Temperature
Safety classification
Directives
Standards
Safety functions
Vibration resistance (DIN EN 60068-2-6)
Shock resistance (DIN EN 60068-2-27)
Shock wave form
Safety classification
MTTF
d
B
Value According to ISO 13849-1 and -2
10D
Common Cause Failure – CCF
Diagnostic coverage
Noise level [dB (A)]
Minimum Operation Frequency
Maximum Cycle Rate
Mounting Orientation
Monitoring
Solenoids
Standard Voltage
Power Consumption (each solenoid)
Current Consumption (each sensor)
Maximum Recommended Allowable
Discordance Time
See online catalog
SV01: 1300 g
SV03: 1700 g
SV05: 3000 g
SV03-AS2: 1900 g
Redundant 5/2 (or 3/2) directional valve
elements of spool construction. (3/2
function is Normally Closed.)
Solenoid pilot operated with spring return.
One solenoid per valve element both to be
operated synchronously
Compressed air according to ISO 8573-1
Class 7:4:4
43 to 145 psi (3 to 10 bar) with internal pilot
supply.
0 to 145 psi (0 to 10 bar) with external pilot
supply. The external pilot pressure must
always be equal or greater than the inlet
pressure and at least 3 bar.
40° to 120°F (4° to 50°C)
See declaration of conformity
ISO 13849-1
"Safe exhaust" and "protection against
unexpected start-up", and "safe cylinder
return" "(depending on the type of the valve)
0.35 mm ± 0.05 mm displacement at
10 Hz...55 Hz
30 g with 18 ms duration
Sinus half-wave
Max. category 4, PL e, SIL 3
See AVENTICS SISTEMA library
See AVENTICS SISTEMA library
> 65
up to high, 99% (depending on the monitoring
system)
W
With silencer, G1/8, 94 dB(A)
W
With silencer, G1/4, 96 dB(A)
W
With silencer, G1/2, 100 dB(A)
We do not recommend using the product
without silencers.
1 x per month, to ensure proper function
2 Hz
Any, preferably vertical
O
Install the valve such that the normal
stroke travel of the valve elements are
perpendicular to the main direction of
machine vibration and/or mechanical
shock.
Dynamic, cyclical, external with customer
supplied equipment. Monitoring should check
state of both valve position sensors with any
and all changes in state of valve control
signals
Per VDE 0580.
Rated for continuous duty. Electrical
connection according to EN 175301-803
Form C.
Enclosure rating according to
IP 65 - IEC 60529 (VDE 0470)
24 volts DC
1.5 Watts per solenoid
< 23 mA
250 msec
Flow Rate [l/min]
Valve
1>2
SV01, 3/2 G1/8"
605
840
SV01, 5/2 G1/8"
SV03, 3/2 G1/4"
690
SV03, 5/2 G1/4"
960
SV05, 3/2 G1/2"
2100
SV05, 5/2 G1/2"
2040
Switching times [ms]
Valve
ON
SV01
20
SV03
30
SV05
40
O
For further technical data, see the catalog pages in the online catalog
(see www.aventics.com/pneumatics-catalog).
2>3
1>4
1300
480
570
1450
680
780
6610
1490
1520
1780
OFF
40
70
180
10
4>5
740
840