Technical Data - Aventics CL03 Notice D'instruction

Masquer les pouces Voir aussi pour CL03:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 105
100
AVENTICS | CL03, CL03-XL | R402000141–BAL–001–AF

Technical Data

Table 7:
Technical data
General data
Valve type
Dimensions
Weight
Operating temperature range
Storage temperature range
Protection acc. to EN 60529/IEC529
Materials
Valve body
Manifold base/valve seals
Permissible medium
Max. particle size
Oil content of compressed air
The pressure dew point must be at least 15°C below the ambient and medium temperatures and must
not exceed 3°C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS.
Operating pressure
Nominal flow
Rated solenoid voltage u
Power consumption per solenoid P
Switching time
Characteristic curve
12 Technical Data
n
20
Spool valve, soft seal
Depends on configuration; (see Fig. 3 on page 67 and Fig. 4.
on page 68)
Depends on configuration (see configurator)
0°C to +50°C, without condensation
–20°C to +70°C
IP69K when assembled
Reinforced fiber-glass polyamide 6
Reinforced fiber-glass polyamide 12
HNBR
Compressed air in accordance with ISO 8573-1:2010
5 μm
3
0-1 mg/m
See table on next page
See table on next page
24 VDC (–15%/+20%)
0.35 W incl. LED and protective circuit
See table on next page
p
= control pressure in bar
c
p
= operating pressure in bar
w