Tabelle 6:
Troubleshooting in the case of malfunctions
Components
Malfunction
Cylinder
Loud impact or cylinder
vibrates in end position
Drop in performance
during continuous
operation
Valve
Pressure/flow level is not
reached or slowly
decreases.
Cylinder with valve Cylinder with valve does
not achieve performance
level
Other defect
AVENTICS | ITS | R412020619–BAL–001–AD
Possible cause
Cushioning too weak
or cylinder
underdimensioned
Cylinder defective
Working pressure too
low
Leakage in the tubing
Tubing too long
If you cannot remedy a malfunction, please contact one of the
addresses found under www.aventics.com.

14 Technical Data

Because the cylinder can be freely configured, not all technical
data can be listed here.
You can find all technical data in the catalog at
www.aventics.com.
This also applies to the 5/2- or 5/3-way valve (CD12 series) as
well as the optionally available coils with electrical connector
(C01 series) and the sensors (SN6, ST6).
Technical Data
Remedy
Correct cushioning
(see page 68)
Replace cylinder
Set a higher working pressure;
Check tubing diameter
Check tubing and its fittings
Reduce tubing length