AVENTICS | CANopen | R402003660–BAL–001–AE
Appendix – bus master configuration
Table 27:
Behavior of the bus coupler in the case of an error
Error case
Comments
BUS OFF
CAN controller is in the "bus off" state,
which means that the "transmit error
counter" of the CAN controller has
exceeded the limit of 256.
Guarding
Node guard monitoring time has run
failure
out. Only occurs when node guarding
has been activated by the CAN master.
Table 26:
Module Control Register
Bit 7
Bit 6
Bit 5
Bit 15
Bit 14
Bit 13
Low Byte
Meaning
Bit 0
Module status in case of error
0
Pre-operational
1
Operational
Bit 2
Bit 1
Outputs in case of error
0
0
CLAB: set outputs to zero (default)
0
1
Last state: Outputs remain in their last state
1
0
Reserved
1
1
Reserved
Bit 3
EMCY reaction in case of error
0
Emergency message is being sent
1
Emergency message is not being sent
Bit 4 to bit 15