AVENTICS | UPG | R412026377–BAL–001–AA | English
Danger of injury due to falling or ejected gripper objects!
If the power supply fails, the gripper objects may fall or be
ejected (depending on the application).
O
Make sure that no persons are in the hazardous area during
operation.
O
Use protective devices to catch any ejected parts (e.g. a
protective grid).
O
Install pressure maintenance valves in your system.
O
Install mechanical devices to retain the gripping force.
Gripping safety when the emergency OFF function is actuated!
Grippers with a mechanical gripping safety can still move
independently in the stipulated direction after an emergency
OFF.
O
Make sure that no persons are in the hazardous area of the
gripper.
8

Service and Repairs

Please use the material numbers listed below to order the
accessory packs from AVENTICS.
Contents of the accessory pack:
W
6 centering sleeves for mounting
W
2 O-rings for tubeless direct connection
W
2 blanking screws for tubing connections
Designation
Accessory pack UPG-P-40
Accessory pack UPG-P-50
Accessory pack UPG-P-64
Accessory pack UPG-P-80
Accessory pack UPG-P-100
Accessory pack UPG-P-125
Accessory pack UPG-P-160
The addresses of our international agencies are available at
www.aventics.com/contact.
9

Disassembly and Exchange

Danger of injury if disassembled under pressure or voltage!
Injuries and damage to the product or system parts may occur if
the pressure and voltage of the system are not switched off
before beginning disassembly.
O
Make sure that the relevant system parts are not under
pressure or voltage.
CAUTION
Mat. no.
R412026315
R412026316
R412026317
R412026318
R412026319
R412026320
R412026321
CAUTION

10 Accessories

The required accessories can be found in our online catalog at
www.aventics.com/pneumatics-catalog
11 Disposal
O
Dispose of the gripper in accordance with your country's
national regulations.

12 Technical Data

Parameter
Operating medium
Nominal operating
pressure
Minimum pressure
without gripping force
retention
with gripping force
retention
Maximum pressure
without gripping force
retention
with gripping force
retention
Pressure range for
sealing air
Further technical data can be found in our online catalog at
www.aventics.com/pneumatics-catalog.
Unit
Limit
Compressed air,
compressed air quality
according to
ISO 8573-1: 7:4:4
bar
6
bar
2.5
4.0
bar
8.0
6.5
bar
0.5 ... 1
9