During assembly
During commissioning
During operation
AVENTICS | CANopen | R402003660–BAL–001–AE
– 24 V DC PELV circuits in accordance with
DIN EN 60204-1/IEC 60204-1.
– The PELV power source must be a safety isolation
transformer in accordance with IEC 61558-1 or
IEC 61558-2-6, or a power source offering the same
degree of safety as a safety isolation transformer.
– Make sure that the power supply of the power pack is
always less than 300 V AC (outer cable – neutral wire).
Switch off the operating voltage before connecting or
disconnecting plugs.
The warranty only applies to the delivered configuration.
The warranty will not apply if the product is incorrectly
assembled.
Make sure the relevant system component is not under
pressure or connected to voltage on assembly or
disassembly. Ensure that the system is protected from
reconnection during assembly work.
Connect the modules and the valve system to functional
earth (FE).
– Connection according to DIN EN 60204-1/IEC 60204-1
Installation may only be performed in a voltage-free and
pressure-free state and only by a qualified technician. In
order to avoid accidents caused by dangerous movements
of the actuators, electrical commissioning is to be carried
out only in a pressure-free state.
Do not put the system into operation before it is completely
assembled as well as correctly wired and configured, and
after it has been tested.
The device is subject to the restrictions of the IP69K
protection class. Before commissioning, make sure that all
the connection seals and plugs are leak-tight to prevent
fluids and foreign bodies from penetrating the device.
Make sure that there is a sufficient exchange of air or
enough cooling if any of the following applies:
– Fully equipped system
– Continuously loaded solenoid valves