Télécharger Imprimer la page

Honda BF40D Manuel D'utilisation page 582

Masquer les pouces Voir aussi pour BF40D:

Publicité

12) Open the harness band clip that clamps the tube A.
Open the harness band clip that clamps the tube A and meter harness A [Equipped type only] (P. 16-38).
1
Replace the harness band clip with a new one on reassembly.
2
Disconnect all of the combination switch connector.
Disconnect the two warning buzzer connectors.
3
4
[1]
COMBINATION
SWITCH
5
6
7
8
9
10
11
12
13) Disconnect all of the indicator light connectors.
13
Remove the indicator light from the tiller handle assembly
14
by pushing the retaining tabs on the right and left sides of
the indicator light as shown.
15
16
17
18
19
20
16-12
[2]
CONNECTOR
[5]
WARNING BUZZER
CONNECTORS
[3]
HARNESS
BAND CLIP
[1]
TILLER HANDLE
ASSEMBLY
[4]
RETAINING
TAB
[3]
INDICATOR
LIGHT
582
[4]
TUBE A
[2]
CONNECTOR
[3]
INDICATOR
LIGHT
[4]
RETAINING
TAB

Publicité

loading

Ce manuel est également adapté pour:

Bf50d