EMOVING THE TOOL FROM THE COLLET CHUCK
5.
Confirm the current message.
The working chamber door closes. The machine
is ready for operation.
Switching off the machine
DANGER
Danger of an electric shock if unplugging
the power cable before switching off the
machine
If you unplug the power cable while the main power
switch is still in "ON" position, residual voltage in the
power cable may cause you to suffer from an electric
shock.
Before
unplugging the power cable, switch off
the machine at the main power switch.
To switch off the machine, do the following:
1.
Ensure that the working chamber is clean.
2.
Switch off the machine at the main power switch.
3.
(Optional) Unplug the power cable.
4.
(Optional) Switch off the main power switch of
your workstation / facility.
Opening & closing the working
chamber door
Damaging of the machine by operating the
working chamber door inappropriately
The working chamber door is operated by electricity.
If you manually open or close the working chamber
door, you can damage the machine.
F
IG
Original Operating Instructions: R5
Version: 5/10/2019
R5 – Operation: Preparing jobs
NOTICE
Manually open or close the working chamber door
only in case of an emergency.
Before
you manually open or close the working
chamber door, read the respective information in
the chapter Operation: Executing jobs.
To open or close the working chamber
door, select the depicted icon in the
Machining
view in DentalCNC.
. 32 – O
&
PENING
CLOSING THE WORKING CHAMBER DOOR