Spécifications techniques
AC30 Series DC Supply Unit Product Order Code
Order example
1
Device Family
380
2
Voltage
5
3
Frame Size and Current Rating
Output drive current rating / Nominal driving power @ 500V
R0094
R0157
S0251
S0394
S0536
Typical example: 380-5R0094-NE-0000 (as shown in the "Order example" above).
This shows the product is an AC30 series regenerative supply unit, rated at 400-500 volts supply, 94A output current rating – 60kW @ 500V,
without a brake switch fitted, Category C3 compliant and no special options.
1
2
3
380
-
5
R
0094
AC30 series regenerative supply unit
400 V - 500 V nominal
94 A / 60 kW
157 A / 100 kW
251 A / 160 kW
394 A / 250 kW
536 A / 340 kW
4
5
6
-
N
E
-
0000
4
Brake Switch
N                                  
Without brake switch (standard)
5
EMC Filter
E                    Category C3 compliant (standard)         
6
Special Options
0000
No special options