Parker AC30 Série Mode D'emploi page 521

Masquer les pouces Voir aussi pour AC30 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PNO
Name
1668
Encoder Speed
1669
Encoder Count Reset
1670
Encoder Count
1671
Encoder Lines
1672
Encoder Invert
1673
Encoder Type
1674
High Input Threshold
1675
Encoder Speed
1676
Encoder Count Reset
1677
Encoder Count
1678
Output Enable
1679
Output Source
1680
Output Voltage
1681
PTP Log Sync Interval
1682
Random Pattern AFE
1683
PTP Clock Mode
1684
PTP Clock Type
1685
PTP Lock Threshold
1686
PTP Priority2
1687
PTP Offset
1688
PTP Locked
1689
PTP State
1690
AFE Close Ext PCR
1691
AFE Ext PCR Closed
1692
AFE PF Angle Demand
1693
AFE Current Control
1694
AFE PLL Kp
1695
AFE PLL Ti
1696
Synth Encoder Lines
1697
AFE VDC Min Level
1698
Synth Encoder Speed
1699
PTP Clock
1701
Switchover Enable
1702
Synth Encoder Invert
1703
AFE Sync Frequency
1704
AFE Id Demand
1705
AFE Iq Demand
1706
AFE Max Current
1707
AFE VDC Kp
1708
AFE VDC Ti
1709
AFE VDC Ramp
1710
AFE VDC Feed Forward
1711
AFE VDC Demand
AC30 series Variable Speed Drive
Path
Type
Monitor::System Board::Encoder Slot 1
REAL
Parameters::System Board::Encoder Slot 1
Same as PNO 1663
BOOL
Same as PNO 1668
DINT
Setup::Inputs and Outputs::SB Encoder Slot2
DINT
Parameters::System Board::Encoder Slot 2
Same as PNO 1671
BOOL
Same as PNO 1671
USINT
(enum)
Same as PNO 1671
BOOL
Monitor::System Board::Encoder Slot 2
REAL
Parameters::System Board::Encoder Slot 2
Same as PNO 1671
BOOL
Same as PNO 1675
DINT
Setup::Inputs and Outputs::System Board Option
BOOL
Parameters::System Board::System Board IO
Same as PNO 1678
USINT
(enum)
Same as PNO 1678
USINT
(enum)
Same as PNO 1661
SINT
Parameters::Motor Control::Pattern Generator
BOOL
Same as PNO 1661
USINT
(enum)
Same as PNO 1661
USINT
(enum)
Same as PNO 1661
REAL
Same as PNO 1661
USINT
Monitor::Communications::PTP
DINT
Parameters::Base Comms::PTP
Same as PNO 1687
BOOL
Same as PNO 1687
USINT
(enum)
Parameters::Regen Control::AFE
BOOL
Parameters::Regen Control::AFE
BOOL
Parameters::Regen Control::AFE
REAL
Setup::Regen Control
BOOL
Parameters::Regen Control::AFE
Parameters::Regen Control::AFE
REAL
Parameters::Regen Control::AFE
REAL
Same as PNO 1678
DINT
Parameters::Regen Control::AFE
REAL
Same as PNO 1678
REAL
Same as PNO 1687
DT
Parameters::Motor Control::MRAS
BOOL
Same as PNO 1678
BOOL
Monitor::Regen Control
REAL
Parameters::Regen Control::AFE
Same as PNO 1693
REAL
Same as PNO 1693
REAL
Parameters::Regen Control::AFE
REAL
Parameters::Regen Control::AFE
REAL
Parameters::Regen Control::AFE
REAL
Parameters::Regen Control::AFE
REAL
Parameters::Regen Control::AFE
REAL
Same as PNO 1693
REAL
Parameter Reference
Default
Range
Units
x.
Min to Max
FALSE
Min to Max
2048
1 to 100000
FALSE
0
Same as PNO 1514
FALSE
x.
Min to Max
FALSE
Min to Max
FALSE
0
0:SYSTEM BOARD SLOT 1
1:SYSTEM BOARD SLOT 2
2:SYNTHETIC ENCDR
3:DIGITAL OUTPUTS
0
Same as PNO 1663
-1
-1 to 0
FALSE
0
0:E2E
0
0:MASTER OR SLAVE
1:SLAVE ONLY
0.5
0.1 to 100.0
128
0 to 255
Min to Max
0:NONE
1:INITIALISNG
2:FAULTY
3:DISABLED
4:LISTENING
5:PRE_MASTER
6:MASTER
7:PASSIVE
8:UNCALIBRATED
9:SLAVE
FALSE
FALSE
0.00
-90.00 to 90.00
FALSE
5.48
0.00 to 30.00
0.0318
0.0000 to 3.0000
2048
1 to 15000000
400.00
340.00 to 5000.00
0
0 to 15000000
1970/01/01 to 2106/02/07
FALSE
FALSE
x.xx
Min to Max
0.10
-1.50 to 1.50
0.00
-1.50 to 1.50
1.50
0.00 to 1.50
8.27
0.00 to 300.00
0.03
0.00 to 3.00
0.05
0.01 to 100.00
0.0000
-1.5000 to 1.5000
720
340 to 820
D-235
WQ
View
Notes
MBus
RPM
NEVER
TECHNICIAN
03863
ALWAYS
TECHNICIAN
2
03865
NEVER
TECHNICIAN
1
03867
STOPPED
TECHNICIAN
03869
STOPPED
TECHNICIAN
03871
STOPPED
TECHNICIAN
03873
STOPPED
TECHNICIAN
03875
RPM
NEVER
OPERATOR
03877
ALWAYS
TECHNICIAN
2
03879
NEVER
TECHNICIAN
1
03881
ALWAYS
ENGINEER
03883
STOPPED
ENGINEER
03885
ALWAYS
ENGINEER
03887
ALWAYS
ENGINEER
03889
ALWAYS
ENGINEER
03891
ALWAYS
ENGINEER
03893
ALWAYS
ENGINEER
03895
us
ALWAYS
ENGINEER
03897
ALWAYS
ENGINEER
03899
ns
NEVER
OPERATOR
03901
NEVER
OPERATOR
03903
NEVER
OPERATOR
03905
ALWAYS
OPERATOR
03907
ALWAYS
OPERATOR
03909
deg
ALWAYS
OPERATOR
03911
ALWAYS
OPERATOR
03913
ALWAYS
OPERATOR
03915
ALWAYS
OPERATOR
03917
ALWAYS
TECHNICIAN
03919
ALWAYS
OPERATOR
03921
RPM
ALWAYS
TECHNICIAN
03923
NEVER
OPERATOR
03925
ALWAYS
ENGINEER
03929
ALWAYS
TECHNICIAN
03931
Hz
NEVER
OPERATOR
3
03933
ALWAYS
OPERATOR
03935
ALWAYS
OPERATOR
03937
ALWAYS
OPERATOR
03939
ALWAYS
OPERATOR
03941
ALWAYS
OPERATOR
03943
%
ALWAYS
OPERATOR
03945
ALWAYS
OPERATOR
03947
V
ALWAYS
OPERATOR
03949

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ac30pAc30dAc30v

Table des Matières