Parameter Name
The maximum operating resolver shaft speed required.
This is set to the application requirements, which must be no greater than the resolver rating.
If the resolver is not the active feedback, this is used to auto-select the best possible speed / position resolution.
Resolver Poles
The number of poles in the resolver.
This is set to the resolver's characteristic
A 2-pole resolver has one sine / cosine amplitude cycle for each mechanical rotation of the shaft.
Resolver Speed Hz
The mechanical gearing of the resolver, reflecting resolver shaft turns per resolver coil turn.
This is set to the resolver's characteristic.
For example, a multi-turn 2-pole resolver, that requires 10 resolver shaft rotations for each sine / cosine amplitude cycle, would use value 10.0.
Resolver Invert
Used to set the direction of rotation which results in the position increasing positively, and the speed reporting as positive.
resolver position
(ENGINEER view level only.)
Actual resolver coil position, expressed as a count value, where one complete amplitude cycle is 65536 counts.
Resolver Turns
The integer number of completed resolver shaft mechanical turns.
Resolver Fraction Turns
The fractional part of the number of resolver shaft mechanical turns.
Resolver Speed Filter
The corner frequency of the speed-tracking, single-order filter applied to the raw resolver speed, before it is reported in the Resolver Speed
parameters or used as speed feedback.
Expressed in terms of the ratio of filter corner frequency to raw resolver cycle frequency.
Used to remove speed ripple caused by the resolver measurement, particularly when the option is used as a reference speed input.
AC30 series Variable Speed Drive
No.
Path
1793
Same as PNO 1790
Parameters::Option IO::Resolver
1822
1810
Same as PNO 1790
1824
Same as PNO 1811
Monitor::Inputs and Outputs
1811
Parameters::Option IO::Resolver
1812
Same as PNO 1811
1815
Same as PNO 1790
Parameter Reference
Default
Range
2,
2 to 100
x.x
FALSE
1000
10 to 10000
D-159
Units
Writable
STOPPED
Hz
NEVER
STOPPED
NEVER
NEVER
NEVER
%
ALWAYS