Parker AC30 Série Mode D'emploi page 192

Masquer les pouces Voir aussi pour AC30 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

12-21
Ethernet
PTP PARAMETER SUMMARY
Note: The value of the PTP configuration parameters only become active when the PTP module initialises, i.e. on inverter power-up, on transition
of the parameter 1661 PTP Enable to TRUE or connection of one or more Ethernet cables.
Parameter Name
PTP Enable
PTP parameter.
Enables the precision time protocol.
PTP Clock Type
PTP parameter.
Sets if the inverter can become a master or slave clock, or a slave clock only.
Enumerated values:
0: MASTER OR SLAVE
1: SLAVE ONLY
PTP Clock Mode
PTP parameter.
Sets the PTP clock mode to either end-to-end (E2E) or peer-to-peer (P2P). See description in section Advanced Users for more
details. Note that currently E2E is only available.
Enumerated values:
0: E2E
PTP Domain
Number
PTP parameter.
Sets the Domain Number of the inverter. A PTP device will only communicate with other PTP devices that have the same domain
number even if it is on the same physical network.
No.
Path
1661
Setup::Communications::PTP
Parameters::Base Comms::PTP
1684
Setup::Communications::PTP
Parameters::Base Comms::PTP
- the device clock will become a Master if it is determined to be the best master in a network,
otherwise it will become a Slave
- the device clock can only become a Slave
1683
Setup::Communications::PTP
Parameters::Base Comms::PTP
1787
Setup::Communications::PTP
Parameters::Base Comms::PTP
Default
Range
FALSE
FALSE
TRUE
0: MASTER OR SLAVE
0:MASTER OR SLAVE
1:SLAVE ONLY
0:E2E
0:E2E
0
0 to
127
Units
Writable
ALWAYS
ALWAYS
ALWAYS
ALWAYS
AC30 series Variable Speed Inverters

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ac30pAc30dAc30v

Table des Matières