PARAMETER SUMMARY
The following parameters are relevant to the EtherNet/IP adapter.
Parameter Name
EtherNet IP Enable
EtherNet/IP adapter parameter.
Enables the built-in EtherNet/IP adapter.
EtherNet IP Trip
EtherNet/IP adapter parameter.
Enables the EtherNet/IP trip on loss of connection.
Enumerated values:
0: DISABLED
1: LOSS OF CONNECTION
EtherNet IP State
EtherNet/IP adapter parameter.
Diagnostic indicating the state of the EtherNet/IP adapter.
Enumerated values:
0: SETUP
1: NW_INIT
2: WAITING TO CONNECT
3: CONNECTION IDLE
4: CONNECTION ACTIVE
5: ERROR
8: NONE
AC30 series Variable Speed Inverter
No.
Path
3128
Setup::Communications::Base EtherNet IP
Parameters::Base Comms::EtherNet IP Adapter
3129
Setup::Communications::Base EtherNet IP
Parameters::Base Comms::EtherNet IP Adapter
- the trip is disabled
- the inverter will trip on the loss of all Class 1 connections
3130
Monitor::Communications::Base EtherNet IP
Parameters::Base Comms::EtherNet IP Adapter
- EtherNet/IP adapter enabled – the inverter is in the configuration state
- network initialization
- waiting for a Class 1 connection
- Class 1 connection made with scanner in Idle mode
- Class 1 connection made with scanner in Run mode
- configuration error
- EtherNet/IP adapter disabled
Default
Range
FALSE
FALSE
TRUE
LOSS OF CONNECTION
0: DISABLED
1: LOSS OF CONNECTION
SETUP
0: SETUP
1: NW_INIT
2: WAITING TO CONNECT
3: CONNECTION IDLE
4: CONNECTION ACTIVE
5: ERROR
6, 7: Reserved
8: NONE
A-30
Fieldbuses
Writable
CONFIG
CONFIG
NEVER