D-150
Parameter Reference
Parameter Name
No.
Lower Input
This is connected to a Digital Input as part of the selected Macro. When TRUE causes Output to ramp down.
Raise Lower Output
1905
The ramp output monitor. Output is preserved during the power-down of the Drive.
Functional Description
The table below describes how Output is controlled by Raise Input, Lower Input and Reset Input.
Reset
TRUE
FALSE
FALSE
FALSE
FALSE
* If Output is greater than Maximum Value the Output will ramp down to Maximum Value at Ramp Time. If Output is less
than Minimum Value the Output will ramp up to Minimum Value at Ramp Time.
IMPORTANT:
If Maximum Value is less than or equal to Minimum Value, then Output is set to Maximum Value.
Path
Monitor::Application::Raise Lower
Raise Input
Raise Output
Any
Any
TRUE
FALSE
FALSE
TRUE
FALSE
FALSE
TRUE
TRUE
Default
Range
0.0
-500.0 to 500.0
Output tracks Reset Value
Output ramps up to Maximum Value at Ramp Time
Output ramps down to Minimum Value at Ramp Time
Output not changed. *
Output not changed. *
Units
Writable
NEVER
Action
AC30 series Variable Speed Drive