D-158
Parameter Reference
Resolver
Setup::Inputs and Outputs::Option
Parameters::Option IO::Resolver
Parameter Name
Resolver Voltage
The r.m.s. amplitude of the sinusoidal excitation voltage output.
This is set to the resolver's requirement.
Setting 0V will disable the excitation output.
Resolver Frequency
The frequency of the sinusoidal excitation voltage output.
This is set to the resolver's requirement.
Resolver Ratio
The ratio of the amplitudes of the sine / cosine feedbacks to the excitation voltage output.
This is set to the resolver's characteristic.
Resolver Max Speed
No.
Path
Setup::Inputs and Outputs::Option
1790
Parameters::Option IO::Resolver
1791
Same as PNO 1790
1792
Same as PNO 1790
Setup::Inputs and Outputs::Option
1825
Parameters::Option IO::Resolver
Default
Range
4
0:0V
1:4V
2:5V
3:6V
4:7V
5:8V
6:9V
7:10V
8:11V
9:12V
8.0
2.0 to 20.0
0.50
0.15 to 3.00
20000
0 to 120000
Units
Writable
STOPPED
kHz
STOPPED
STOPPED
RPM
STOPPED
AC30 series Variable Speed Drive