Parker AC30 Série Mode D'emploi page 297

Masquer les pouces Voir aussi pour AC30 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Parameter Name
No.
Link to digital output to send command to close external pre charge
1691
AFE Ext PCR Closed
Link to digital input to provide information if external pcr is closed.
1703
AFE Sync Frequency
Mains frequency as measured by the AFE module.
1718
AFE Sync Angle
Mains angle as measured by the AFE module.
1694
AFE PLL Kp
PLL proportional gain.
1695
AFE PLL Ti
PLL integral term.
1707
AFE VDC Kp
DC link voltage loop proportional gain.
1708
AFE VDC Ti
DC link voltage loop integral term.
1711
AFE VDC Demand
AC30 series Variable Speed Drive
Path
Parameters::Regen Control::AFE
Monitor::Regen Control
Parameters::Regen Control::AFE
Parameters::Regen Control::AFE
Parameters::Regen Control::AFE
Parameters::Regen Control::AFE
Parameters::Regen Control::AFE
Parameters::Regen Control::AFE
Same as PNO 1693
Parameter Reference
Default
Range
FALSE
5.48
0.00 to 30.00
0.0318
0.0000 to 3.0000
8.27
0.00 to 300.00
0.03
0.00 to 3.00
720
340 to 820
D-11
Units
Writable
ALWAYS
Hz
NEVER
deg
NEVER
ALWAYS
ALWAYS
ALWAYS
ALWAYS
V
ALWAYS