Parameter Reference
PNO
Name
1545
Cut Off Frequency
1546
Frequency 1
1547
Frequency 2
1548
Factor
1549
Application Volts
1550
Nameplate Mag Current
1551
Product Code Flags
1554
Application Name
1560
Start Delay Enable
1565
Local Power Up Mode
1567
Modbus Mapping
1568
Modbus Mapping[0]
1569
Modbus Mapping[1]
1570
Modbus Mapping[2]
1571
Modbus Mapping[3]
1572
Modbus Mapping[4]
1573
Modbus Mapping[5]
1574
Modbus Mapping[6]
1575
Modbus Mapping[7]
1576
Modbus Mapping[8]
1577
Modbus Mapping[9]
1578
Modbus Mapping[10]
1579
Modbus Mapping[11]
1580
Modbus Mapping[12]
1581
Modbus Mapping[13]
1582
Modbus Mapping[14]
1583
Modbus Mapping[15]
1632
Mapping Valid
1633
Application User Boost
1634
Start Delay
1635
Delay To Start
1636
Manufacturing Flags
1637
Engineer Password
1640
Modbus Password
1641
VDC Lim Enable
1642
VDC Lim Level
1643
VDC Lim Active
1644
VDC Lim Output
1645
Pwrl Enable
1646
Pwrl Trip Threshold
1647
Pwrl Control Band
1648
Pwrl Accel Rate
1649
Pwrl Decel Rate
1650
Pwrl Time Limit
1651
Pwrl Active
1658
Current Diff Level
1659
Modbus TCP Password
1661
PTP Enable
1663
Encoder Supply
1664
Encoder Lines
1665
Encoder Invert
1666
Encoder Type
1667
High Input Threshold
Path
Type
Parameters::Motor Control::Filter On Torque Dmd
REAL
Parameters::Motor Control::Filter On Torque Dmd
REAL
Parameters::Motor Control::Filter On Torque Dmd
REAL
Parameters::Motor Control::Filter On Torque Dmd
REAL
Parameters::Motor Control::Fluxing VHz
REAL
Setup::Motor Control::Autotune
REAL
Parameters::Motor Control::Autotune
Parameters::Device Manager::Drive info
BYTE
Parameters::Application::App Info
STRING[20]
Parameters::Motor Control::Motor Sequencer
BOOL
Parameters::Motor Control::Sequencing
USINT
(enum)
Setup::Communications::Base Modbus
ARRAY[0..15]
Parameters::Base Comms::Modbus
Same as PNO 1567
UINT
Same as PNO 1567
UINT
Same as PNO 1567
UINT
Same as PNO 1567
UINT
Same as PNO 1567
UINT
Same as PNO 1567
UINT
Same as PNO 1567
UINT
Same as PNO 1567
UINT
Same as PNO 1567
UINT
Same as PNO 1567
UINT
Same as PNO 1567
UINT
Same as PNO 1567
UINT
Same as PNO 1567
UINT
Same as PNO 1567
UINT
Same as PNO 1567
UINT
Same as PNO 1567
UINT
Monitor::Communications::Base Modbus
BOOL
Parameters::Base Comms::Modbus
Parameters::Motor Control::Fluxing VHz
REAL
Parameters::Motor Control::Motor Sequencer
TIME
Parameters::Motor Control::Motor Sequencer
TIME
Parameters::Device Manager::Drive info
WORD
Parameters::Keypad::Graphical Keypad
WORD
Setup::Communications::Option
WORD
Parameters::Option Comms::Modbus RTU
Parameters::Motor Control::DC Link Volts Limit
BOOL
Parameters::Motor Control::DC Link Volts Limit
REAL
Parameters::Motor Control::DC Link Volts Limit
BOOL
Parameters::Motor Control::DC Link Volts Limit
REAL
Parameters::Motor Control::Power Loss Ride Thru
BOOL
Parameters::Motor Control::Power Loss Ride Thru
REAL
Parameters::Motor Control::Power Loss Ride Thru
REAL
Parameters::Motor Control::Power Loss Ride Thru
REAL
Parameters::Motor Control::Power Loss Ride Thru
REAL
Parameters::Motor Control::Power Loss Ride Thru
TIME
Parameters::Motor Control::Power Loss Ride Thru
BOOL
Parameters::Trips::Current Sensor Trip
REAL
Setup::Communications::Base Modbus
WORD
Parameters::Base Comms::Modbus
Setup::Communications::PTP
BOOL
Parameters::Base Comms::PTP
Setup::Inputs and Outputs::SB Encoder Slot1
USINT
Parameters::System Board::Encoder Slot 1
(enum)
Same as PNO 1663
DINT
Same as PNO 1663
BOOL
Same as PNO 1663
USINT
(enum)
Same as PNO 1663
BOOL
Default
Range
Units
2000
20 to 6000
2000
20 to 6000
2000
20 to 6000
0.20
0.10 to 1.00
0.00
0.00 to 150.00
1.00
0.01 to 1000.00
FALSE
0
0:AS WHEN POWERED DOWN
1:LOCAL
2:REMOTE
0000
0000 to 3131
0000
0000 to 3131
0000
0000 to 3131
0000
0000 to 3131
0000
0000 to 3131
0000
0000 to 3131
0000
0000 to 3131
0000
0000 to 3131
0000
0000 to 3131
0000
0000 to 3131
0000
0000 to 3131
0000
0000 to 3131
0000
0000 to 3131
0000
0000 to 3131
0000
0000 to 3131
0000
0000 to 3131
0.00
0.00 to 25.00
0.000
0.000 to 30.000
0.000 to Max
0000
0000
FALSE
91.0
78.0 to 100.0
x.x
Min to Max
FALSE
52.0
20.0 to 60.0
2.0
0.0 to 20.0
100
1 to 500
100
1 to 500
30.000
0.000 to 300.000
25.00
0.00 to 100.00
0000
FALSE
0
0:5 V
1:12 V
2:15 V
3:20 V
2048
1 to 100000
FALSE
0
Same as PNO 1514
FALSE
WQ
View
Notes
MBus
Hz
ALWAYS
TECHNICIAN
03617
Hz
ALWAYS
TECHNICIAN
03619
Hz
ALWAYS
TECHNICIAN
03621
ALWAYS
TECHNICIAN
03623
%
ALWAYS
OPERATOR
03625
A
STOPPED
TECHNICIAN
6
03627
NEVER
ENGINEER
03629
NEVER
TECHNICIAN
03635
STOPPED
TECHNICIAN
03647
ALWAYS
TECHNICIAN
03657
ALWAYS
ENGINEER
03661
ALWAYS
ENGINEER
03663
ALWAYS
ENGINEER
03665
ALWAYS
ENGINEER
03667
ALWAYS
ENGINEER
03669
ALWAYS
ENGINEER
03671
ALWAYS
ENGINEER
03673
ALWAYS
ENGINEER
03675
ALWAYS
ENGINEER
03677
ALWAYS
ENGINEER
03679
ALWAYS
ENGINEER
03681
ALWAYS
ENGINEER
03683
ALWAYS
ENGINEER
03685
ALWAYS
ENGINEER
03687
ALWAYS
ENGINEER
03689
ALWAYS
ENGINEER
03691
ALWAYS
ENGINEER
03693
NEVER
OPERATOR
03791
%
ALWAYS
OPERATOR
03793
s
STOPPED
TECHNICIAN
03795
s
NEVER
TECHNICIAN
03797
NEVER
ENGINEER
03799
ALWAYS
TECHNICIAN
03801
ALWAYS
TECHNICIAN
03807
STOPPED
TECHNICIAN
03809
%
STOPPED
TECHNICIAN
03811
NEVER
TECHNICIAN
03813
Hz
NEVER
ENGINEER
03815
STOPPED
TECHNICIAN
03817
%
STOPPED
TECHNICIAN
03819
%
STOPPED
TECHNICIAN
03821
Hz/s
STOPPED
TECHNICIAN
03823
Hz/s
STOPPED
TECHNICIAN
03825
s
STOPPED
TECHNICIAN
03827
NEVER
TECHNICIAN
03829
%
ALWAYS
OPERATOR
03843
ALWAYS
TECHNICIAN
03845
ALWAYS
TECHNICIAN
03849
STOPPED
TECHNICIAN
03853
STOPPED
TECHNICIAN
03855
STOPPED
TECHNICIAN
03857
STOPPED
TECHNICIAN
03859
STOPPED
TECHNICIAN
03861