Parameter Name
No.
Digin Value
0005
Presents all the digital inputs to the drive as a 16-bit word. The bits within the word may be accessed individually, or the entire word
may be accessed as a group.
Bit
Signal name
0
Digital Input 01
1
Digital Input 02
2
Digital Input 03
3
Digital Input 04
4
Digital Input 05
5
Digital Input 06
6
Digital Input 07
7
STO Inactive
8
Digital Input 11
9
Digital Input 12
10
Digital Input 13
11
Digital Input 14
12
Run Key
13
Not Stop Key
14
Stop Key
* If the GKP is not fitted then both "Not Stop Key" and "Stop Key" will be 0. This condition may be used to detect a disconnected GKP.
AC30 series Variable Speed Drive
Path
Monitor::Inputs and Outputs
Parameters::Inputs And Outputs::IO
Values
Terminal
Comment
X13.2
X13.3
X13.4
X12.1
Common terminal with digital output 1
X12.2
Common terminal with digital output 2
X12.3
Common terminal with digital output 3
X12.4
Common terminal with digital output 4
X10
X20.1
GPIO option
X20.2
GPIO option
X20.3
GPIO option
X20.4
GPIO option
-
GKP Run key pressed*
-
GKP Stop key not pressed*
-
GKP Stop key pressed*
Parameter Reference
Default
Range
0:Digin 01
1:Digin 02
2:Digin 03
3:Digin 04
4:Digin 05
5:Digin 06
6:Digin 07
7:STO Inactive
8:Digin 11
9:Digin 12
10:Digin 13
11:Digin 14
12:Run Key
13:Not Stop Key
14:Stop Key
PNO for individual bit access
0006
0007
0008
0009
0010
0011
0012
0013
0014
0015
0016
0017
0018
0019
0020
D-99
Units
Writable
NEVER