PMAC Motor Data
Setup::Motor Control::MotorData PMAC
Parameters::Motor Control::PMAC Motor Data
Only available if PMAC Motor selected in Control Mode.
The PMAC Motor Data contains the parameters needed to run and control of a PMAC motor. A PMAC motor is a Permanent Magnet AC Motor with
sinusoidal back EMF.
Parameter Name
No.
PMAC Max Speed
0555
Set the motor's rated speed in rpm.
PMAC Max Current
0556
Set the motor's maximum current ( Amps rms ).
PMAC Rated Current
0557
Set the motor's rated current ( Amps rms ).
Refer to Motor Current Percent in the Feedbacks function. A value of 100% = PMAC rated Current.
PMAC Rated Torque
0558
Set the motor's rated torque.
Refer to Actual Torque in the Feedbacks function. A value of 100% = PMAC Rated Torque.
PMAC Motor Poles
0559
Set the number of motor poles, e.g. for a 4 poles motor enter "4".
AC30 series Variable Speed Drive
Path
Setup::Motor Control::Motor Data PMAC
Parameters::Motor Control::PMAC Motor
Data
Same as PNO 555
Same as PNO 555
Same as PNO 555
Same as PNO 555
Parameter Reference
Default
Range
3000
0 to 100000
4.50
0.00 to 5000.00
4.50
0.00 to 5000.00
4.50
0.00 to 30000.00
10
0 to 400
D-121
Units
Writable
ALWAYS
RPM
A
ALWAYS
A
ALWAYS
ALWAYS
Nm
ALWAYS