D-236
Parameter Reference
PNO
Name
1712
AFE Synchronizing
1713
AFE Synchronized
1714
AFE Enable Drive
1715
AFE Phase Loss
1716
AFE Brake Mode
1717
AFE Correction Angle
1718
AFE Sync Angle
1721
AFE Status
1722
SB Digital Input 2
1723
SB Digital Input 3
1725
Peer to Peer Enable
1726
Destination IP Address
1727
Destination Port
1728
Local Port
1729
Peer to Peer State
1730
AFE Inductance
1731
AFE Transf Angle Offset
1732
Motor Start Count
1733
Time Since Power-On
1734
AR Trip Mask B
1735
AR Trip Mask 2 B
1736
AR Initial Delay B
1737
AR Repeat Delay B
1738
Enable Auto Save
1739
System Board Required
1740
System Board Fitted
1741
System Board Status
1742
System Board FE State
1743
Encoder Feedback
1744
Slave Position Src
1745
Master Position Src
1746
Speed Error Trip Enable
1747
Speed Error Threshold
1748
Speed Error Trip Delay
1749
Setup Successful
1750
Error Number
1751
Master Encoder
1752
Slave Encoder
Path
Type
Parameters::Regen Control::AFE
BOOL
Parameters::Regen Control::AFE
BOOL
Parameters::Regen Control::AFE
BOOL
Parameters::Regen Control::AFE
BOOL
Parameters::Regen Control::AFE
BOOL
Parameters::Regen Control::AFE
REAL
Parameters::Regen Control::AFE
REAL
Same as PNO 1703
USINT
(enum)
Monitor::Inputs and Outputs
BOOL
Parameters::System Board::System Board IO
Same as PNO 1722
BOOL
Setup::Communications::Peer to Peer
BOOL
Parameters::Base Comms::Peer to Peer
Same as PNO 1725
DWORD
(IP addr)
Same as PNO 1725
UINT
Same as PNO 1725
UINT
Monitor::Communications::Peer to Peer
USINT
Parameters::Base Comms::Peer to Peer
(enum)
Setup::Regen Control
REAL
Parameters::Regen Control::AFE
Parameters::Regen Control::AFE
REAL
Parameters::Device Manager::Runtime Statistics
UDINT
Parameters::Device Manager::Runtime Statistics
TIME
Parameters::Motor Control::Auto Restart
DWORD
Parameters::Motor Control::Auto Restart
DWORD
Parameters::Motor Control::Auto Restart
TIME
Parameters::Motor Control::Auto Restart
TIME
Parameters::Device Manager::Setup Wizard
BOOL
Setup::Inputs and Outputs::System Board Option
USINT
Parameters::System Board::System Board Option
(enum)
Parameters::System Board::System Board Option
USINT
(enum)
Parameters::System Board::System Board Option
USINT
(enum)
Parameters::Device Manager::Device State
USINT
(enum)
Setup::Motor Control::Control and Type
USINT
Parameters::Control Mode::Control Mode
(enum)
Parameters::Phase Control::Configure
USINT
(enum)
Parameters::Phase Control::Configure
USINT
(enum)
Parameters::Trips::Speed Error Trip
BOOL
Parameters::Trips::Speed Error Trip
REAL
Parameters::Trips::Speed Error Trip
TIME
Parameters::Phase Control::Configure
BOOL
Parameters::Phase Control::Configure
INT
Parameters::Phase Control::Configure
USINT
(enum)
Parameters::Phase Control::Configure
USINT
(enum)
Default
Range
Units
FALSE
0.00
-90.00 to 90.00
x.xx
Min to Max
0:INACTIVE
1:SYNCHRONIZING
2:SYCHRONIZED
3:SUPPLY FREQ HIGH
4:SUPPLY FREQ LOW
5:SYNC FAILED
FALSE
255.255.255.255
1250
1 to 65535
1250
1 to 65535
0:DISABLED
1:ACTIVE
2:ERROR
0.00
0.00 to 1000.00
0.00
0.00 to 360.00
0 to Max
0.000 to Max
00000000
00000000
60.000
0.000 to 3600.000
120.000
0.000 to 3600.000
TRUE
0
0:NONE
1:DUAL ENCODER
Same as PNO 1739
Same as PNO 1180
Same as PNO 989
0
0:MAIN SPD FEEDBACK
1:SYSTEM BOARD SLOT 1
2:SYSTEM BOARD SLOT 2
3:NONE
0
0:SAME AS MOTOR FBK
1:MAIN SPD FEEDBACK
2:SYSTEM BOARD SLOT 1
3:SYSTEM BOARD SLOT 2
3
Same as PNO 1743
TRUE
50.00
0.00 to 100.00
10.000
0.000 to 2000.000
-32768 to 32767
0:EMPTY FUNC
1:ESTIMATOR
2:PRIMARY
3:SYSTEM BOARD SLOT 1
4:SYSTEM BOARD SLOT 2
5:OTHER
Same as PNO 1751
WQ
View
Notes
MBus
NEVER
OPERATOR
3
03951
NEVER
OPERATOR
3
03953
NEVER
OPERATOR
3
03955
NEVER
OPERATOR
3
03957
ALWAYS
OPERATOR
03959
ALWAYS
OPERATOR
03961
deg
NEVER
OPERATOR
3
03963
NEVER
OPERATOR
3
03969
NEVER
OPERATOR
03971
NEVER
OPERATOR
03973
ALWAYS
TECHNICIAN
03977
ALWAYS
ENGINEER
03979
ALWAYS
ENGINEER
03981
ALWAYS
ENGINEER
03983
NEVER
OPERATOR
03985
mH
ALWAYS
OPERATOR
03987
deg
ALWAYS
OPERATOR
03989
NEVER
TECHNICIAN
1
03991
s
NEVER
TECHNICIAN
03993
ALWAYS
TECHNICIAN
03995
ALWAYS
TECHNICIAN
03997
s
ALWAYS
OPERATOR
03999
s
ALWAYS
OPERATOR
04001
ALWAYS
ENGINEER
04003
CONFIG
TECHNICIAN
04005
NEVER
OPERATOR
1
04007
NEVER
OPERATOR
04009
NEVER
OPERATOR
04011
STOPPED
TECHNICIAN
6
04013
STOPPED
TECHNICIAN
6
04015
STOPPED
TECHNICIAN
6
04017
ALWAYS
TECHNICIAN
04019
%
ALWAYS
TECHNICIAN
04021
s
ALWAYS
TECHNICIAN
04023
NEVER
TECHNICIAN
04025
NEVER
TECHNICIAN
04027
NEVER
TECHNICIAN
04029
NEVER
TECHNICIAN
04031
AC30 series Variable Speed Drive