Parker AC30 Série Mode D'emploi page 409

Masquer les pouces Voir aussi pour AC30 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Parameter Name
No.
1387
PMAC Base Volt
Rated motor rated voltage in Volt rms
1808
PMAC Encoder Offset
Only available if 1533 Control Type = ENCODER FEEDBACK
Electrical position Offset between encoder Zero position and motor Back EMF
Automatically set up if Alignment sequence runs and completed
1809
PMAC Wiring
Only available if 1533 Control Type = ENCODER FEEDBACK
Wiring direction of the motor phase :
-
STANDARD : U V W
-
REVERSE : U W V
Allow to change connection of phase V and W internally to the drive. No external action required.
Automatically set up if Alignment sequence runs and completed.
Changing this parameter will change the direction of motor rotation.
application.
AC30 series Variable Speed Drive
Path
Setup::Motor Control::Motor Data PMAC
Parameters::Motor Control::PMAC Motor
Data
Setup::Motor Control::Motor
Data PMAC
Parameters::Motor
Control::PMAC Motor Data
Setup::Motor Control::Motor
Data PMAC
Monitor::Motor and Drive
Parameters::Motor
Control::PMAC Motor Data
Parameter Reference
Default
Range
400.00
0.00 to 1000.00
0.0
-180.0 to 180.0
0
Same as PNO 1804
Please verify if the new direction is compatible with your
D-123
Units
Writable
ALWAYS
V
deg
ALWAYS
ALWAYS

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ac30pAc30dAc30v

Table des Matières