PNO
Name
0361
Slew Rate Accel Limit
0362
Slew Rate Decel Limit
0364
Stabilisation Enable
0371
Terminal Voltage Mode
0374
Motor Base Volts
0380
Power kW
0381
Power HP
0382
Reactive Power
0383
Energy kWh
0385
Power Factor Est
0386
Power Factor Angle Est
0389
Reset Energy Meter
0390
Duty Selection
0392
DC Link Voltage
0393
Actual Speed RPM
0394
Actual Speed rps
0395
Actual Speed Percent
0396
DC Link Volt Filtered
0397
id
0398
iq
0399
Actual Torque
0400
Actual Field Current
0401
Motor Current Percent
0402
Motor Current
0403
100% Stack Current A
0404
Stack Current (%)
0405
Motor Terminal Volts
0406
CM Temperature
0407
Heatsink Temperature
0408
Elec Rotor Speed
0410
Archive Flags
0412
Stack Frequency
0413
Random Pattern IM
0414
Deflux Delay
0415
Positive Torque Lim
0416
Negative Torque Lim
0417
Main Torque Lim
0418
Fast Stop Torque Lim
0419
Symmetric Torque Lim
0420
Actual Pos Torque Lim
0421
Actual Neg Torque Lim
0422
VHz Shape
0423
VHz User Freq
0424
VHz User Freq[0]
0425
VHz User Freq[1]
0426
VHz User Freq[2]
0427
VHz User Freq[3]
0428
VHz User Freq[4]
0429
VHz User Freq[5]
0430
VHz User Freq[6]
0431
VHz User Freq[7]
0432
VHz User Freq[8]
0433
VHz User Freq[9]
0434
VHz User Freq[10]
AC30 series Variable Speed Drive
Path
Type
Parameters::Motor Control::Slew Rate
REAL
Parameters::Motor Control::Slew Rate
REAL
Parameters::Motor Control::Stabilisation
BOOL
Parameters::Motor Control::Voltage Control
USINT
(enum)
Parameters::Motor Control::Voltage Control
REAL
Monitor::Energy Meter
REAL
Parameters::Motor Control::Energy Meter
Same as PNO 380
REAL
Same as PNO 380
REAL
Same as PNO 380
REAL
Same as PNO 380
REAL
Parameters::Motor Control::Energy Meter
REAL
Parameters::Motor Control::Energy Meter
BOOL
Setup::Motor Control::Control and Type
USINT
Parameters::Motor Control::Feedbacks
(enum)
Monitor::Motor and Drive
REAL
Monitor::Regen Control
Parameters::Motor Control::Feedbacks
Monitor::Motor and Drive
REAL
Parameters::Motor Control::Feedbacks
Same as PNO 393
REAL
Same as PNO 393
REAL
Same as PNO 393
REAL
Parameters::Motor Control::Feedbacks
REAL
Parameters::Motor Control::Feedbacks
REAL
Same as PNO 393
REAL
Same as PNO 393
REAL
Same as PNO 393
REAL
Same as PNO 393
REAL
Parameters::Motor Control::Feedbacks
REAL
Parameters::Motor Control::Feedbacks
REAL
Same as PNO 393
REAL
Same as PNO 393
REAL
Same as PNO 393
REAL
Parameters::Motor Control::Feedbacks
REAL
Parameters::Application::App Info
WORD
Parameters::Motor Control::Pattern Generator
REAL
Parameters::Motor Control::Pattern Generator
BOOL
Parameters::Motor Control::Pattern Generator
TIME
Parameters::Motor Control::Torque Limit
REAL
Parameters::Motor Control::Torque Limit
REAL
Setup::Motor Control::Control and Type
REAL
Parameters::Motor Control::Torque Limit
Parameters::Motor Control::Torque Limit
REAL
Parameters::Motor Control::Torque Limit
BOOL
Monitor::Motor and Drive
REAL
Parameters::Motor Control::Torque Limit
Same as PNO 420
REAL
Setup::Motor Control::Control and Type
USINT
Parameters::Motor Control::Fluxing VHz
(enum)
Parameters::Motor Control::Fluxing VHz
ARRAY[0..10]
Parameters::Motor Control::Fluxing VHz
REAL
Parameters::Motor Control::Fluxing VHz
REAL
Parameters::Motor Control::Fluxing VHz
REAL
Parameters::Motor Control::Fluxing VHz
REAL
Parameters::Motor Control::Fluxing VHz
REAL
Parameters::Motor Control::Fluxing VHz
REAL
Parameters::Motor Control::Fluxing VHz
REAL
Parameters::Motor Control::Fluxing VHz
REAL
Parameters::Motor Control::Fluxing VHz
REAL
Parameters::Motor Control::Fluxing VHz
REAL
Parameters::Motor Control::Fluxing VHz
REAL
Parameter Reference
Default
Range
Units
500
1 to 1200
500
1 to 1200
TRUE
0
0:NONE
1:FIXED
2:AUTOMATIC
100.00
0.00 to 115.47
x.xx
0.00 to 1000000.00
x.xx
0.00 to 1000000.00
x.xx
0.00 to 1000000.00
x.xx
0.00 to 10000000.00
x.xx
0.00 to 1.00
x.xx
0.00 to 90.00
FALSE
1
0:HEAVY DUTY
1:NORMAL DUTY
x.
0 to 1000
x.xx
-100000.00 to 100000.00
x.xx
-1500.00 to 1500.00
x.xx
-200.00 to 200.00
x.
0 to 1000
x.x
-600.0 to 600.0
x.x
-600.0 to 600.0
x.x
-600.0 to 600.0
x.x
-200.0 to 200.0
x.x
0.0 to 600.0
x.x
0.0 to 2000.0
x.x
0.0 to 2000.0
x.
0 to 500
x.
0 to 1000
x.x
-25.0 to 200.0
x.x
-25.0 to 200.0
x.x
-1500.0 to 1500.0
4.00
2.00 to 16.00
TRUE
1.000
0.000 to 10.000
150.0
-600.0 to 600.0
-150.0
-600.0 to 600.0
150.0
0.0 to 600.0
150.0
0.0 to 600.0
FALSE
x.x
-600.0 to 600.0
x.x
-600.0 to 600.0
0
0:LINEAR LAW
1:FAN LAW
2:USER DEFINED
3:APPLICATION DEFINED
0.0
0.0 to 100.0
10.0
0.0 to 100.0
20.0
0.0 to 100.0
30.0
0.0 to 100.0
40.0
0.0 to 100.0
50.0
0.0 to 100.0
60.0
0.0 to 100.0
70.0
0.0 to 100.0
80.0
0.0 to 100.0
90.0
0.0 to 100.0
100.0
0.0 to 100.0
D-217
WQ
View
Notes
MBus
Hz/s
ALWAYS
TECHNICIAN
01249
Hz/s
ALWAYS
TECHNICIAN
01251
ALWAYS
TECHNICIAN
01255
ALWAYS
TECHNICIAN
01269
%
ALWAYS
TECHNICIAN
01275
kW
NEVER
TECHNICIAN
01287
HP
NEVER
TECHNICIAN
01289
kVAr
NEVER
TECHNICIAN
01291
kWh
NEVER
TECHNICIAN
1
01293
NEVER
TECHNICIAN
01297
deg
NEVER
TECHNICIAN
01299
ALWAYS
TECHNICIAN
2
01305
STOPPED
TECHNICIAN
01307
V
NEVER
TECHNICIAN
01311
RPM
NEVER
TECHNICIAN
01313
rev/s
NEVER
TECHNICIAN
01315
%
NEVER
OPERATOR
01317
V
NEVER
TECHNICIAN
01319
%
NEVER
TECHNICIAN
01321
%
NEVER
TECHNICIAN
01323
%
NEVER
TECHNICIAN
01325
%
NEVER
TECHNICIAN
01327
%
NEVER
TECHNICIAN
01329
A
NEVER
TECHNICIAN
01331
A
NEVER
TECHNICIAN
01333
%
NEVER
TECHNICIAN
01335
V
NEVER
TECHNICIAN
01337
°C
NEVER
TECHNICIAN
01339
°C
NEVER
TECHNICIAN
01341
Hz
NEVER
OPERATOR
01343
NEVER
OPERATOR
01347
kHz
ALWAYS
ENGINEER
6
01351
ALWAYS
ENGINEER
01353
s
STOPPED
ENGINEER
6
01355
%
ALWAYS
TECHNICIAN
01357
%
ALWAYS
TECHNICIAN
01359
%
ALWAYS
TECHNICIAN
01361
%
ALWAYS
TECHNICIAN
01363
ALWAYS
TECHNICIAN
01365
%
NEVER
TECHNICIAN
01367
%
NEVER
TECHNICIAN
01369
STOPPED
TECHNICIAN
01371
STOPPED
ENGINEER
01373
%
STOPPED
ENGINEER
01375
%
STOPPED
ENGINEER
01377
%
STOPPED
ENGINEER
01379
%
STOPPED
ENGINEER
01381
%
STOPPED
ENGINEER
01383
%
STOPPED
ENGINEER
01385
%
STOPPED
ENGINEER
01387
%
STOPPED
ENGINEER
01389
%
STOPPED
ENGINEER
01391
%
STOPPED
ENGINEER
01393
%
STOPPED
ENGINEER
01395