Parker AC30 Série Mode D'emploi page 472

Masquer les pouces Voir aussi pour AC30 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

D-186
Parameter Reference
Speed Ref
Parameters::Motor control::Speed Ref
This function holds all the parameters concerning the generation of the setpoint reference (reference ramp, speed trim, setpoint reverse, etc.).
Parameter Name
No.
Ref Min Speed Clamp
1264
Minimum value for Ramp Speed Output
Ref Max Speed Clamp
1265
Maximum value for Ramp Speed Output
Ref Speed Trim
1266
The trim is added to the ramp output to form the Ramp Speed Output (unconditionally in remote mode).
In local mode, it is added is the Ref Trim Local parameter is set to TRUE
Ref Trim Local
1267
When TRUE, the trim is added to the ramp output in local mode.
When FALSE, the trim is not added to the ramp output in local mode.
Path
Parameters::Motor Control::Speed Ref
Parameters::Motor Control::Speed Ref
Parameters::Motor Control::Speed Ref
Parameters::Motor Control::Speed Ref
Default
Range
-110.00
-110.00 to 0.00
110.00
0.00 to 110.00
0.00
-300.00 to 300.00
FALSE
Units
Writable
%
ALWAYS
ALWAYS
%
ALWAYS
%
ALWAYS
AC30 series Variable Speed Drive

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ac30pAc30dAc30v

Table des Matières