en-US
Fig. 12: Removing the Wilo-Connector
2.
Undo the metal clamp from the mechanical lock on the housing using suitable tools.
For this purpose, move the tools toward the outside and simultaneously open the metal clamp toward
the housing.
3.
Pull off the Wilo-Connector.
NOTICE
For confined installation situations (e.g. shut-off valves directly below the electrical connec-
tion), an angle plug is available as an alternative. Angle plug to be ordered separately!
7.5
Connecting communication interfaces
Observe all warnings in the "Electrical Connection" section!
Make sure that all power supplies of the pump and connected communication interfaces, especially that
of SSM (FAULT) and SBM (RUN), are switched off!
38
Installation and operating instructions • Wilo-Stratos MAXO/-D/-Z • Ed.02/2023-10