Connection
Analog input 2 (AI2)
Wilo Net
*
Cable length ≥ 6½ ft (2 m): Use shielded cables.
**
If using wire end ferrules, the maximum cross-section at communication interfaces reduces to 17 AWG.
All combinations up to 14 AWG are permissible in the Wilo-Connector.
Table 8: Cable requirements
DANGER
Electric shock!
If connecting SSM (FAULT)/SBM (RUN) conductors, ensure separate cable routing to the
SELV section, otherwise SELV protection can no longer be guaranteed!
At cable cross-sections of 0.2 ... 0.39 inches, remove the inner seal ring from the threaded cable gland before
installing the cable.
Ø 0.12 - 0.2 in
Ø 3-5 mm
Ø 0.2 - 0.39 in
Ø 5-10 mm
Fig. 9: Threaded cable gland Ø 0.2-0.39 inches
NOTICE
• Tighten the M16x1.5 threaded cable gland on the electronic module with a torque of
22.1 inlb.
• Tighten nuts with a torque of 22.1 inlb to ensure strain relief.
• Remove the inner seal ring of the threaded cable gland when installing cables with a di-
ameter ≥ 0.2 inches.
32
Cable cross-section
Min.
2x24 AWG
3x24 AWG
Installation and operating instructions • Wilo-Stratos MAXO/-D/-Z • Ed.02/2023-10
Cable cross-section
Max.
2x16 AWG
**
(17 AWG
3x16 AWG
**
(17 AWG
Ø 0.2-0.39 in
Ø 5-10 mm
2.3
Cable
*
)
shielded
)
2.2
2.1