CAUTION
Property damage caused by chemical disinfectants!
Chemical disinfectants can cause material damage.
• Remove the pump for the duration of chemical disinfection!
Permitted temperatures
Fluid temperature
Ambient temperature
Table 6: Permitted temperatures
4.2
Improper use
WARNING! Improper use of the pump can result in hazardous situations and damage.
•
Never use other fluids.
•
Easily flammable materials/fluids must be kept out of reach of the product.
•
Never have unauthorized work carried out.
•
Never operate outside the application limits indicated.
•
Never carry out unauthorized modifications.
•
Only use authorized accessories and original spare parts.
•
Never operate with phase angle control/phase-fired control.
4.3
Safety instructions
Electrical current
DANGER
Electric shock!
The pump is electrically operated. There is a risk of fatal injury from electric shock!
• Only have work on electrical components carried out by qualified electricians.
• Before all work, deactivate the power supply (if necessary, SSM and SBM) and safeguard
against accidental switch-on. Due to the presence of dangerous contact voltage, work
on the electronic module must not be started until 5 minutes have elapsed.
• Only operate the pump with intact components and connection pipes.
Installation and operating instructions • Wilo-Stratos MAXO/-D/-Z • Ed.02/2023-10
Stratos MAXO/-D
14 °F (-10 °C) ... 230 °F
(+110 °C)
14 °F (-10 °C) ... 104 °F
(+40 °C)
Stratos MAXO-Z
32 °F (0 °C) ... 176 °F (+80 °C)
32 °F (0 °C) ... 104 °F (+40 °C)
en-US