Télécharger Imprimer la page

Wilo Stratos MAXO Notice De Montage Et De Mise En Service page 19

Publicité

Les langues disponibles

Les langues disponibles

CAUTION
Property damage caused by chemical disinfectants!
Chemical disinfectants can cause material damage.
• Remove the pump for the duration of chemical disinfection!
Permitted temperatures
Fluid temperature
Ambient temperature
Table 6: Permitted temperatures
4.2
Improper use
WARNING! Improper use of the pump can result in hazardous situations and damage.
Never use other fluids.
Easily flammable materials/fluids must be kept out of reach of the product.
Never have unauthorized work carried out.
Never operate outside the application limits indicated.
Never carry out unauthorized modifications.
Only use authorized accessories and original spare parts.
Never operate with phase angle control/phase-fired control.
4.3
Safety instructions
Electrical current
DANGER
Electric shock!
The pump is electrically operated. There is a risk of fatal injury from electric shock!
• Only have work on electrical components carried out by qualified electricians.
• Before all work, deactivate the power supply (if necessary, SSM and SBM) and safeguard
against accidental switch-on. Due to the presence of dangerous contact voltage, work
on the electronic module must not be started until 5 minutes have elapsed.
• Only operate the pump with intact components and connection pipes.
Installation and operating instructions • Wilo-Stratos MAXO/-D/-Z • Ed.02/2023-10
Stratos MAXO/-D
14 °F (-10 °C) ... 230 °F
(+110 °C)
14 °F (-10 °C) ... 104 °F
(+40 °C)
Stratos MAXO-Z
32 °F (0 °C) ... 176 °F (+80 °C)
32 °F (0 °C) ... 104 °F (+40 °C)