Télécharger Imprimer la page

Stop Switch - Honda EU65is Mode D'emploi

Masquer les pouces Voir aussi pour EU65is:

Publicité

cap.15 EU65is 6500is 07.12.17 5:06 PM ページ15-3
c. INSPECTION
• LED
1) Disconnect the red lead connector and black lead
connector.
2) Check for continuity between the terminals according to
the table below.
(–) Probe
(+) Probe
Male terminal
(Red lead)
Female terminal
(Black lead)
• When using the multimeter, perform this inspection at
mark position.
• START SWITCH
1) Disconnect the lead connectors from the start switch.
2) Check for continuity between the terminals of the switch.
There should be continuity when the switch button pushed.
There should be no continuity when the switch button
released.

• STOP SWITCH

1) Disconnect the lead connectors from the ignition switch.
2) Check for continuity between the terminals of the switch.
There should be continuity when the switch button pushed.
There should be no continuity when the switch button
released.
15-3
Male terminal
Female terminal
(Red lead)
(Black lead)
Continuity
No continuity

Publicité

Chapitres

loading

Ce manuel est également adapté pour:

Eu6500is