cap.10 EU65is 6500is 07.12.17 4:56 PM ページ10-2
6) Remove the four 10 mm flange nuts and remove the
ground cable.
7) Remove the engine/generator assembly.
8) Remove the 8 x 30 mm flange bolts and rear engine mount
bracket.
9) Installation is the reverse order of the removal. Note the
following.
10) Install the ground terminal, and tighten the ground
terminal bolt to the specified torque.
TORQUE: 3 N . m (0.3 kgf . m, 2.2 Ibf . ft)
[1]
ENGINE/GENERATOR
ASSEMBLY
[3]
10 mm
FLANGE NUT (4)
10-2
8 x 30 (2)
[1]
10 mm
FLANGE
NUT
[2]
GROUND CABLE
[2]
REAR ENGINE MOUNT
BRACKET