cap.04 EU65is 6500is (Eu).qxd 07.12.17 4:46 PM ページ4-10
c. CLEANING
To prevent serious eye injury, always wear safety goggles or
other eye protection when using compressed air.
NOTICE
• Some commercially available chemical cleaners are very
caustic. These cleaners may damage plastic parts such as O-
rings, floats and float seats. Check the container for
instructions. If you are in doubt, do not use these products to
clean Honda carburetors.
• High air pressure may damage the carburetor. Use low air
pressure [206 kPa (2.11 kgf/cm
passages and ports.
1) Clean the carburetor body with high flash point solvent.
2) Use low air pressure and clean the following passages and
ports:
– Vent port
– Pilot screw hole
– Pilot jet hole
– Pilot air jet
– Main air jet
– Transition ports
– Pilot outlet
– Main nozzle holder
d. INSPECTION
• FLOAT LEVEL HEIGHT
Place the carburetor in the position shown and measure the
distance between the float top and carburetor body when the
float just contacts the seat without compressing the valve
spring.
Standard float height
If the height is outside the specification, replace the float and
recheck the float height.
TOOL:
Float level gauge
• THROTTLE/CHOKE CONTROL MOTOR
Measure the resistance between the terminals.
Standard
resistance
If the height is outside the specification, replace the float and
recheck the float height.
4-10
CAUTION
2
, 30 psi) or less] when cleaning
13.2 mm (0.52 in)
07401-0010000
Between 1 and 3: 50 – 70 Ω
Between 2 and 4: 50 – 70 Ω
[1] ENGINE BLOCK SIDE:
[3]
TRANSITION
PORTS
[6]
[5] AIR CLEANER SIDE:
PILOT SCREW
HOLE
[10]
PILOT JET
HOLE
[9]
MAIN NOZZLE
HOLDER
[1] FLOAT LEVEL GAUGE
07401-0010000
1
2
3
[2] VENT PORT
[4] PILOT OUTLET
[7] PILOT AIR JET
[8] MAIN AIR JET
4