Fault
The appliance does not
switch on
Smell of gas
Cooking cycle does not start
or stops suddenly
The cleaning cycle does not
start or stops suddenly
The burner does not light or
goes out suddenly
Burner does not light or goes
out suddenly with "E12" alarm
signalled
If the problem or fault noticed is not amongst those
listed in the table, consult the "Key to Alarms" table
provided below.
The information provided below s intended to
identify the alarm signals which appear on the
display (A).
NOTE: Press RESET to reset the alarm and
the cooking cycle restarts automatically. Press
START if the cooking cycle does not restart auto-
matically.
44
FAULT
TROUBLESHOOTING
Cause
Fuse "blown"
Safety or protection device (safety
thermostat or overload cutout) tripped
Electronic circuit board damaged
Gas leaks in supply system
Control board electronic circuit board
damaged
Alarm triggered
Control board electronic circuit board
damaged
Alarm triggered
Gas valve faulty
Air intake in base obstructed
Ignition plug wires disconnected or
damaged
Ignition plugs dirty or damaged
Ignition monitoring device faulty
TABLE OF ALARM INDICATIONS
Remedy
Replace the fuse (see "installation
manual")
Press device reset button
Contact the after-sales service
Check the tightness of the system
Contact the after-sales service
Consult the "Key to Alarms" table
Contact the after-sales service.
Consult the "Key to Alarms" table
Replace gas valve
Clean the air intake
Reconnect or replace the wires
Clean or replace the plugs
Replace the device