SERVICING
CLEANING THE CONDENSATION COLLECTION CHANNEL AND TANK
To carry out this operation, proceed as follows.
1) Clean and drain the condensation collection channel (A).
2) Clean the condensation collection tank (B) and check that the drain hole and line are not blocked.
To carry out this operation, proceed as follows.
1) Switch off the appliance.
2) Turn off the circuit-breaker to disconnect it from
the electrical mains.
3) Open the fi lter door under the appliance and ex-
tract the air fi lter (C) and clean it.
Users
To carry out this operation, proceed as follows.
1) Run the steam oven at 100°C for half an hour.
2) Switch off the oven and disconnect the power supply switch.
3) Spray cleaning solution from the end of the vent hose (A) and let it sit for at least 15 minutes.
4) Rinse the hose by spraying water into it from the end that opens onto the oven ceiling (do this with
the side of the oven closed).
5) Manually rinse the inside of the cooking chamber or run an automatic rinse program.
3354462_ATG_ut_GB_rev.2
CLEANING THE AIR FILTERS
VENT CLEANING