ENGLISH
To carry out this operation, proceed as follows.
1) Undo the screws to remove the side panel (A).
2) Open the tangs (B) and remove the guard (C).
3) Undo the nuts (D) to remove the ignition plug unit (E).
4) Replace the guard and close the tangs when done.
APPLIANCE DECOMMISSIONING, DEMOLITION AND DISPOSAL
When decommissioning the appliance, a series of procedures must be carried out to ensure that the
appliance and its components are not a hindrance and are not easily accessible.
To ensure that the appliance cannot constitute hazards for people or the environment, all energy
sources (electricity, etc.) must be disconnected and rendered unusable, and any liquids present must be
drained (lubricants, fl uids, etc.).
Place the appliance in a suitable area which is not easily accessible, with barriers to prevent anyone from
accessing it.
When scrapping, sort all components by chemical characteristics and dispose of them separately in ac-
cordance with the relevant legal requirements.
IMPORTANT: Do not dump non-biodegradable products, lubricating oils, and non-metal-
lic components (rubber, PVC, resins, etc.) in the environment. Dispose of them in compliance with
the relevant laws.
18
CHANGING THE IGNITION PLUG
A
C
B
D
E
D
REPLACING PARTS