ENGLISH
Adjust the fl oor-mounted feet (A) to level the
appliance.
WARNING: Do not tilt the appliance and
wheeled accessories more than 10°.
WARNING: The connection must be made by authorised, skilled personnel, in accordance
with the relevant legal requirements, using appropriate and specifi ed materials. The appliance is
supplied with operating voltage 230V/1N 50 Hz (230V/1N 60 Hz available on request)(see atta-
ched wiring diagrams).
HAZARD: Before doing any work, cut off the mains electricity supply.
Connect the appliance to the mains electricity supply as follows.
1) If not already present, install an automatic circuit-
breaker (B), protecting only each single appliance
and located close to it, with the following charac-
teristics.
– Thermal breaker device (to adjust see table on
page 3 of the user instructions manual)
– Diff erential breaker set at 30 mA
– Class B or C (IEC 898)
2) Undo the screws and remove the side panel (A).
3) Connect the automatic circuit-breaker (B) to the
appliance's terminal board (C) and to the electri-
cal mains supply, in accordance with the electrical
system diagram provided at the back of the manual
and using a cable with the following characteristics.
– Weight: ≥ than H05RN-F type (designation 245 IEC
57)
– Temperature of use: ≥70°C.
WARNING: When connecting, take care to connect the phase and neutral lines.
4) Replace the panel and retighten the screws when the operation is complete.
WARNING: Make the connection in com-
pliance with the relevant legal requirements,
using appropriate and recommended materials.
To make the connection, connect the mains line to
the appliance's connection pipe, fi tting a shut-off tap
(A), to allow the gas supply to be cut off when neces-
sary.
WARNING: The tap (A), not supplied with
the appliance, must be installed in an easily ac-
cessible position and its status (on or off ) must be
obvious at a glance.
10
LEVELLING
ELECTRICAL CONNECTION
GAS CONNECTION
A
HANDLING AND INSTALLATION
A
B
A
C