Installation and Operating Specification FU Comfort Sinus
Max. Speed
(11D)
Override Time
(21D)
Setpoint1/2
(5D)
Setpoint int./ext.
(6D)
Protection Mode
(34D)
Setpoint1/2
(5D)
Setpoint int./ext.
(6D)
Control/Manual
(7D)
Heating/Cooling
(8D)
1.Setp+Pband1/2
(15D)
E1 / E2
(4D)
2. Setpoint 1/2
(9D)
2.Setp+Pband1/2
(16D)
Analogue input E2
Function
OFF
1E
4E
Ext. Setpoint
(1E)
Ext. Manual mode
(2E)
Average E1
(3E)
L-BAL-E304-GB 2004
Setting Max. Speed "ON" / "OFF"
Influences the respectively set value "1. Max. Speed" and "2. Max. Speed" in operation
with two control circuits.
Overwrite timer function (in operation with timer)
For Mode Speed controller
Switch over "Set Intern1" / "Set Intern2"
"Setting External 1" must be at "OFF".
Switch over "Intern" / "Extern"
Fixed allocation for D2 with programmed Protection Mode for activation
For modes as controller higher
Switch over "Setpoint 1" / "Setpoint 2"for control circuit1
Switch over "Intern" / "Extern"
Possible only for operation with one control circuit!
Switch over "automatic control" / "Speed manual"
Possible only for operation with one control circuit!
Switch over control function (e.g. "heating" / "cooling")
for control circuit 1: Switch over Setpoint 1/2 and Pband 1/1
When programming this function, "Setting" additionally lists the parameter: "1.Pband 1.
for control circuit 1"
Only active in operation with a second control circuit
The output for control circuit 2 is set additionally to "A2" to "A1" (regardless of the
|
programmed function for
A1
the switch over.
The switch over input "E1" / "E2" as in operation with one control circuit is no longer
possible.
for control circuit 2: Switch over "Setpoint 1" / "Setpoint 2"
for control circuit 2: Switch over Setpoint 1/2 and Pband 1/2
When programming this function, "Setting" additionally lists the parameter: "2.Pband 2
for control circuit 2"
Description Function E2
no function (factory setting)
For mode speed controller
Operation with a second setting signal (switch over "E1" <-> "E2" via floating contact)
Operation with a second setting signal and automatic control at the higher level ("E1" <-
> "E2")
For modes as controller higher
|
|
= External Setpoint e.g. via external signal (0 - 10 V) instead of "Setpoint 1"
1E
External manual operation via external signal (0 - 10 V). Switch over between settings
on the device and external manual operation via digital input.
Sensor average to E1
Part.-No.
110/139
1.01
2.01
|
). The first control circuit has no output for the duration of
1.01
2.01
Menu tables