Menu Structure - Helios FU Comfort Sinus Manuel De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation and Operating Specification FU Comfort Sinus
8.4

Menu structure

Esc
Info
Main menu
Start
Setting
Protocol
0 %
Base setup
Frequency
Controller
Setup
P↓ ↑ ESC
▲ ▼
Info
Start
0.0 A
Motor current
PIN input
▲ ▼
Info
Start
25.0 Hz
Set external1
Language
Start
US units
Menu dependent on mode
Selection of the menu group (e.g. Base setup) to the right through the ▼-key, to the left through the ▼-key.
You can go to the menu items in the menu groups (e.g. mode of operation) by using the P key. Use the arrow keys to move up
and down within the menu group.
The menu groups consist of one area for the user (user menu) and one area for installation (service). The service area can be
protected against unauthorized access by using a PIN.
In order to simplify the initial start-up operation, the service level is enabled at first (i.e., not protected by the PIN 0010 (see
Operating Instructions / Controller Setup, PIN protection = OFF). If PIN protection is activated (ON), the service menu remains
enabled after input of PIN 0010 as long as one is pressing keys. If no keys are pressed for ca. 15 minutes, the PIN is
automatically erased, i.e. the service level is blocked.
To make adjustments, press the P key after selecting the menu item. If the previously set value starts to flash, it can be adjusted
with the ▼ + ▲ keys and then saved with the P key. To exit the menu without making any changes, use the "Esc" short-key, i.e.,
the originally set values remain.
Information
After installation of the device has been carried out, PIN protection should be activated (see Operating
Instructions / Controller Setup)!
L-BAL-E304-GB 2004
← ← ← ←
Main menu
Start
Setting
Protocol
Base setup
Controller
Setup
P↓ ↑ ESC
Setting
- - - -
50 Hz
Set Internal1
▲ ▼
▲ ▼
Setting
D
- - - -
Set Internal2
▲ ▼
▲ ▼
Setting
OFF
OFF Hz
Min. Speed
PIN 0010
User
Service
Main menu
Main menu
Start
Start
Setting
Setting
Protocol
Protocol
Base setup
Base setup
Controller
Controller
Setup
Setup
P↓ ↑ ESC
Protocol 1/22
Base setup
Sensor1
OTC
000022:45:10
▲ ▼
Protocol 2/22
Base setup
MODBUS
Komm.
OTC
E1 Analog In
000018:05:10
Base setup
Part.-No.
32/139
Controls and Menu
→ → → →
Main menu
Start
Setting
Protocol
Base setup
Controller
Setup
P↓ ↑ ESC
P↓ ↑ ESC
Controller
Setup
1.01
OFF
Mode
PIN Protection
▲ ▼
▲ ▼
Controller
Setup
0 - 10V
OFF
Set protection
▲ ▼
▲ ▼
Controller
Setup
OFF
OFF
Save User
E2 Function
Setup

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fu-cs82937. 002/0220

Table des Matières