SOLENOID VALVE SYSTEM
EC651032
INSPECTION STEPS
If the solenoid valve will not operate, use the following inspection steps.
Check each couplers and
wire connection.
OK
Check solenoid valve.
OK
* Check CDI magneto.
OK
Replace CDI unit.
* marked: Refer to "IGNITION SYSTEM" section.
NOTE:
9 Remove the following parts before inspection.
1) Seat
2) Fuel tank
9 Use l2V battery in this inspection.
9 Use the following special tools in this inspection.
Pocket tester:
YU-3112-C/90890-03112
SOLENOID VALVE SYSTEM
No good
Check solenoid
valve operation.
Solenoid valve
coil
Source coil
6-7
ELEC
Repair or replace.
No good
No good
No good
Replace.
Replace.
Replace.