Moniteur multiparamètres

Publicité

Les langues disponibles

Les langues disponibles

➢ Parameter Settings
Parameter 1 and 2 is fixed to be ECG and SpO
settings are OFF, TEMP, NIBP, and RESP.
Note
Waveform 1- 5 and Parameter 1 - 5 are corresponding to the waveform 1- 5 and Parameter
1- 5. Similarly, in other views, the waveform 1- 5 and Parameter 1- 5 corresponds to that in
the View settings window.
5.2.2 Big Font View
Description
In this view, the default 3 waveform channels in the waveform area are ECG waveform, SpO
and RESP waveform. Moreover, the default 4 parameter panels in the parameter area are the ECG Panel,
SpO
Panel, NIBP Panel, and RR panel.
2
Big Font View Settings
➢ Waveform Settings
Wave 1 can be set as any ECG lead, or turn off this channel directly.
Wave 2 and Wave 3 can be set as OFF, another ECG wave different from that selected in Wave I,
SpO
, and RESP (or CO
2
and RESP (or CO
➢ Parameter Settings
"Param 1", "Param 2," and "Param 4" can be set as OFF, ECG, SpO
"Param 3" can be set as ECG, TEMP, NIBP, SpO
Cascaded above: select it means all first 3 channels waveform display the waveform set in
Waveform 1, and waveform 2 and waveform 3 are the cascaded waveform of Waveform 1.
Moreover, at the moment, Wave 2 and Wave 3 are nonadjustable. The default is deselected.
Close all waveforms: Select it means waveform 1 to waveform 3 does not display on the waveform
panel in the big font view, but the information in the parameter panel displays.
5.2.3 All ECG Trace view
Description
In this View, all ECG trace waveforms display on-screen simultaneously. All 7 traces of ECG waveform display
on the left and the 5 parameter panels are on the right.
All ECG Trace View Settings
The default 12 waveforms displaying in the view are: ECG I, ECG II, ECG III, ECG aVR, ECG aVL, ECG aVF, ECG
V1, ECG V2, ECG V3, ECG V4, ECG V5, ECG V6, waveform 1~12 are nonadjustable.
The default 7 waveforms displaying in the view are ECG I, ECG II, ECG III, ECG aVR, ECG aVL, ECG aVF, and
ECG V, waveform 1~7 are nonadjustable.
Parameter 1 and Parameter 2 are nonadjustable; the default settings are ECG and SpO
respectively.
respectively, which cannot be adjusted. Parameter 3 to 7
2,
). If "3-lead wires" is selected, then Wave 2 and Wave 3 can be set as SpO
2
), or set as the current cascaded ECG waveform (e.g., ECGII).
2
2,
and RESP (or CO
)
2,
2
38
plethysmogram,
2
NIBP, TEMP, and RESP (or CO
2,
,
2
).
2