Conversion For Lp Or Ng Gas; Electric Gas Ignition; The Burner Flames - Fulgor Milano SOFIA FSRC 4807 2P MK 2F Serie Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

9 - Conversion for LP or NG Gas

EN
Proper adjustment will produce a stable, steady blue flame
of minimum size.
The final adjustment should be checked by turning the knob
from high to low several times without extinguishing the
flame.
This adjustment, at low setting, will automatically provide
the proper flame size at medium setting.
After Conversion steps have been completed, check the
appearance of each burner's flame at the HI and LO
settings, if the flames appear too large or too small review
each step to make sure it was completed correctly.
NOTE: To obtain the correct minimum setting with
LP gas, turn clockwise tightening the valve(s)
fully with the thin-blade screwdriver into
the recess behind control knob (A and / or
B).

Electric Gas Ignition

The gas burners use an electric ignition device located near
each burner ensures burners ignite automatically.
ELECTRIC IGNITION
See Use & Care manual for better explanation
and its control.
26

The Burner Flames

Turn each burner on. Flames should be blue in color with no
trace of yellow. The burner flames should not flutter or blow
away from the burner The inner cone of the flame should be
between 1/2" and 3/4" long.
BURNER FLAMES
1/2" to 3/4"
BURNER