QUALIFIED SERVICE MAN OR GAS APPLIANCE
INSTALLER
MUST
MAKE
CONNECTION.
Leak testing of the appliance shall be conducted by the
installer according to the instructions given.
Instructions for Installation Of The
Appliance (Positioning and ventilation
requirements)
The regulations covering the installation, maintenance and
operation of gas appliances for domestic use are applicable
regulations. An extract of these regulations appears below.
For all indications not covered, refer to the above-mentioned
regulations.
Positioning
The products of combustion from cooking appliances must
always be discharged into suitable extractor hoods, which
must be connected to a chimney, flue or vented directly to
outside the building. In situations where it is not possible to
install an extractor hood, an electric extractor fan installed
in a window or external wall may be used, provided that all
requirements of the ventilation regulations are satisfied; the
fan should switch on whenever the appliance is in operation.
VENTILATION
Ventilation
It is essential that the room in which gas appliances are
installed is adequately ventilated to ensure that all the
appliances receive the required quantity of fresh air for
combustion. To ensure an adequate air flow, it may be
necessary to create apertures in accordance with the
following requirements:
a) with cross-sectional area of 6 cm
cross-sectional area of 100 cm
be created by increasing the gap between the bottom of
doors and the floor);
b) situated at the bottom of an external wall, preferably
opposite the wall on which combustion products are
extracted ;
THE
GAS
SUPPLY
per kW with a minimum
2
(these apertures may also
2
7 - Gas Requirement
c) the positions of the apertures should selected so as to
avoid the possibility of their being obstructed and,
if made in external walls, they must be protected with
grilles, metal meshes, etc. installed on the outside face of
the wall.
If an electric extractor fan for the removal of foul air is
installed in the room, the apertures provided for air changes
must allow a ventilation rate of at least 35 m
power installed.
Gas Connection
The oven is designed to operate with both natural gas
(methane) and liquid gas (LPG), and can be easily converted
from one type to another following the instructions given in
the relative section of this booklet.
Connection to the gas supply must be carried out by qualified
technicians and in conformance with the requirements.
If the appliance is to operate with gas bottles (LPG), a
pressure regulator conforming to the requirements.
Rigid Pipe Connection
Connection to the mains gas supply may be made via a
rigid pipe firmly attached to the fitting "G", or via a flexible
stainless steel continuous-wall hose, conforming with a
maximum length of 2 metres.
The fitting "G" and seal "C" are supplied with the appliance,
and comply with standards.
IMPORTANT
Use two wrenches to turn the fitting "G" to the required
position. When the fitting is in the desired position, firmly
tighten nut "A".
RIGID PIPE CONNECTION
G
A
B
IMPORTANT
After connecting the appliance to the gas supply (or to the
liquid gas bottles) CHECK FOR LEAKS at the union using
a solution of soapy water (never use a naked flame).
EN
/h per kW of
3
C
17

Publicité