Before moving the range, protect any finished flooring and
secure oven door(s) closed to prevent damage.
Vent hood Combinations:
It is recommended that these ranges be installed in
conjunction with a suitable overhead vent hood.
Due to the high heat capacity of this unit, particular attention
should be paid to the hood and ductwork installation to
assure it meets local building codes.
WARNING
Air curtain or other overhead hoods, which operate by
blowing a downward air flow on to a range, shall not be
used in conjunction with ranges with gas cooktop other
than when the hood and range have been designed,
tested and certified by an independent test laboratory for
use in combination with each other.
Clearances to horizontal surfaces above the range,
measured to the cooking surface are below. Failure to
comply may result in fire hazard.
• A custom hood installation with exposed horizontal
combustible surfaces must have an Auto-On feature.
• For other installations with a hood, refer to the hood
installation instructions for specific hood clearances.
CAUTION
These ranges weigh up to 400 pounds (180Kg). Some
disassembly will reduce the weight considerably. Due to
the weight and size of the range and to reduce the risk of
personal injury or damage to the product:
TWO
PEOPLE
ARE
INSTALLATION.

Anti-Tip Bracket Installation

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Ensure the anti-tip bracket is engaged when the range is
moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death or
serious burns to children and adults.
4 - Product Dimensions and Cutout Requirements
REQUIRED
FOR
PROPER
WARNING
To verify the anti-tip bracket is installed and engaged:
• Slide range forward.
• Look for the anti-tip bracket securely attached to floor
or wall.
• Slide range back so rear range foot is under anti-tip
bracket.
• See installation instructions for details.
ANTI-TIP BRACKET INSTALLATION
BACKWALL
CABINET
SIDEWALL
ANTI-TIP
FLUSH
BRACKET
For Concrete or Cement Construction:
You must use appropriate fastening hardware (not
provided).
Secure the bracket to the wall and/or floor with at least
4 wood screws (provided).
The anti-tip bracket should be inserted into the opening
on the anti-tip brace on the range.
EN
Anti-Tip Bracket
Range Foot
WALL
ANCHOR
11