4 - Product Dimensions and Cutout Requirements
EN
2" (5,1) max.
protusion from wall
for gas or electrical supply
The surface of the entire back wall above the range and below the hood must be covered with a noncombustible material.
*Consult local code for exact location requirements.
OPENING WIDTH
Range 48"
Minimum clearances:
Above cooking surface (above 36" [91.4 cm])
• Sides - 6" (15.2 cm)
• Within 6" (15.2 cm) side clearance, wall cabinets
no deeper than 13" (33.0 cm) must be minimum 18"
(45.7 cm) above cooking surface
• Rear - 0" with 9 " backguard; 0" with non-combustible
rear wall.
Below cooking surface (36" [91.4 cm] and below)
• Install
with
zero
combustible construction below the cooking surface
and the back and sides of the appliance.
10
CUTOUT REQUIREMENTS
min 18" (45,7)
min 6" (15,2)
A & B
48" (122)
clearance
between
adjacent
B
min 25 1/2" (65)
Minimum to
Combustibles
or to botton of
ventilation hood
min 18" (45,7)
A
3" ( 9 )
3" ( 9 )
GAS
ELECTRIC
min 4 3/4" (12,3)
ADDITIONAL CLEARANCES:
For island installation, maintain 2-½ in. minimum from
cutout to back edge of countertop and 3 in. minimum
from cutout to side edges of countertop (see top view).
For island installation, 12" (305) minimum clearance
back of range to combustible rear wall above countertop.
FLUSH ISLAND INSTALLATION
min 3" (7.6)
max 13" (33)
min 6" (15,2)
BACK
min 2 1/2" (6.3)
min 3" (7.6)