Conversion of the Valve System

12.7 New PLC configuration for the valve system

Configuration error!
An incorrect valve system configuration can cause malfunctions in and damage to the overall
system.
The configuration may therefore only be carried out by an electrical specialist!
Observe the specifications of the system owner as well as any restrictions resulting from
the overall system.
Observe the documentation of your configuration program.
After converting the valve system, you need to configure the newly added components.
In the PLC configuration software, adapt the number of input and output objects to the valve
system.
Because the data is mapped to the PDO in physical sequence, the position of the data in the PDO will
shift if an additional module is used. However, if you add a module at the left end of the I/O modules,
with an output module nothing will be shifted. Only the object of the new module must be added. With
an input module, only the two diagnostic objects will be shifted by the newly added object.
After converting the valve system, always make sure the input and output objects are still
correctly assigned.
If you have exchanged components without changing their order, you do not need to reconfigure
the valve system. All components will be recognized by the controller.
For the PLC configuration, proceed as described in section 5 "PLC Configuration of the Valve
System" on page 80.