AVENTICS | Bus Coupler AES/Valve Driver AV, Ethernet POWERLINK | R412018143–BAL–001–AF

About This Product

12
Fig. 1:
Ethernet POWERLINK bus coupler
4
About This Product
4.1

Bus coupler

The AES series bus coupler for Ethernet POWERLINK V2 establishes communication between
the superior controller and connected valves and I/O modules. It is designed only for use as a slave
in an Ethernet POWERLINK V2 bus system in accordance with IEC 61158 and IEC 61784-2, CPF 13.
Therefore, the bus coupler must be configured. The CD R412018133, included on delivery, contains
an XDD file for the configuration (see section 5.2 "Loading the device description file" on page 80).
During cyclical data transfer, the bus coupler can send 512 bits of input data to the controller and
receive 512 bits of output data from the controller. To communicate with the valves, an electronic
interface for the valve driver connection is located on the right side of the bus coupler. The left side
of the device contains an electronic interface which establishes communication with
the I/O modules. The two interfaces function independently.
The bus coupler can actuate a maximum of 64 single or double solenoid valves (128 solenoid coils)
and up to 10 I/O modules. It supports 100 Mbit half-duplex data communication. The minimum
POWERLINK cycle time is 400 ms if 42 objects or fewer are mapped. If more than 42 objects are
mapped, the minimum cycle time is 1 ms.
All electrical connections are located on the front side, and all status displays on the top.
1
10
9
10
11
10
9
1 Identification key
2 LEDs
3 Window
4 Field for equipment ID
5 X7E1 fieldbus connection
6 X7E2 fieldbus connection
7 X1S power supply connection
2
3
4
5
6
7
8
8 Ground
9 Base for spring clamp element mounting
10 Mounting screws for mounting on transition
plate
11 Electrical connection for AES modules
12 Rating plate
13 Electrical connection for AV modules
13

Publicité